Operation Manual / 4 Product description / A130-M.. - A145-M..
5 Operation and service / 5.3 Expected replacement intervals
© Copyright 2020 ABB. All rights reserved. HZTL4031_EN Rev.L July 2020
Influencing parameters
The specified values are guideline values and are not guaranteed. The actual values can devi-
ate considerably from the guideline values, for example, due to the following influences:
¡ Fuel quality and fuel treatment
¡ Load profile (thermal cycling, also number of starts/stops, emergency shutdowns, oper-
ating point)
¡ Gas inlet temperature
¡ Frequency and execution of cleaning process during operation
¡ Turbocharger specification.
¡ System-specific operating conditions (combustion quality, exhaust gas composition)
For bearing parts
¡ Lubricating oil quality (oil filtering, oil condition, oil monitoring)
¡ Load profile (speed, pressure conditions, temperature)
¡ Number of starts/stops
¡ Unbalance of the rotor (degree of contamination).