EasyManua.ls Logo

ABB ACS255 - User Manual

ABB ACS255
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
ABB Micro drives
User’s manual
ACS255 drives (0.5…20 hp) (600V Variants)

Table of Contents

Other manuals for ABB ACS255

Questions and Answers

  • K
    kimberly53Sep 12, 2025
    How to troubleshoot CAN Open comms trip on ABB ACS255?
    • V
      Veronica JacobsSep 12, 2025
      To troubleshoot a CAN Open comms trip on your ABB Controller, check that the network master/PLC is still operating and inspect the connection cables. Increase the value of parameter 3018 to a suitable level.
  • K
    Kristen KrauseSep 14, 2025
    What causes a lost 4-20mA signal on ABB ACS255?
    • M
      Mary WoodSep 14, 2025
      If you've lost a 4-20mA signal on your ABB Controller, check the signal source and wiring to the ACS255 terminals.
  • A
    anthonymurphySep 16, 2025
    What does motor PTC over temperature mean on ABB Controller?
    • J
      Jerry OrtizSep 16, 2025
      A motor PTC over temperature indication on your ABB Controller means that the connected motor PTC device has caused the drive to trip.
  • V
    vazquezlisaNov 18, 2025
    What to do if ABB ACS255 shows instantaneous over current due to excess motor load?
    • B
      brianmathisNov 18, 2025
      If the fault occurs on drive enable, inspect the motor and its connection cable for phase-to-phase and phase-to-earth short circuits. Verify the load isn't jammed, blocked, or stalled mechanically. Ensure the motor nameplate parameters are correctly entered in parameters 9905, 9906, and 9907. If operating in Vector mode (Parameter 9903 – 0 or 1), also check the motor power factor in parameter 9915 and ensure an autotune has been successfully completed for the connected motor. Reduce the Boost voltage setting in parameter 2603. Increase the ramp up time in parameter 2202. If the connected motor has a holding brake, ensure the brake is correctly connected and controlled, and is releasing correctly. If the fault occurs when running in Vector mode (parameter 9903 – 0,1,3), reduce the speed loo...

Summary

Declaration of Conformity

STO Function

Details on the Safe Torque Off function compliance.

Electromagnetic Compatibility

EMC compliance categories and requirements.

2. Safety

Safety in installation and maintenance

Safety instructions for installation and maintenance tasks.

Safety in start-up and operation

Safety guidelines for starting up and operating the drive.

5. Electrical Installation

Grounding and EMC Compliance

Proper grounding and EMC installation practices for the drive.

Wiring Precautions and Power Connection

Important wiring precautions and incoming power connection instructions.

Drive and Motor Connections

Connecting the drive to the motor and thermal protection.

Control Terminal Wiring and Connections

Wiring control terminals and connection diagram details.

5.10. Safe Torque Off (STO)

Information about the Safe Torque Off (STO) function.

6. Managing the Keypad

Keypad Layout and Function

Explains the drive keypad buttons and their functions.

Changing Parameters

Step-by-step guide to changing drive parameters.

Resetting Parameters to Factory Default Settings

Procedure to reset drive parameters to factory defaults.

7. Quick Start-up and Control

Quick Start-up Terminal Control

Guide for initial setup using terminal control.

Quick Start-up Keypad Control

Guide for initial setup using keypad control.

8. Application Macros

Macro wiring configurations

Wiring diagrams for various application macro configurations.

9.4. Parameters in the Long parameter mode

2102 STOP MODE

Selection of drive stop modes (ramp, coast).

22 ACCEL;DECEL

Parameters for acceleration and deceleration ramp times.

53 COMMUNICATIONS PARAMETERS

Parameters for drive communication settings.

99 START-UP DATA

Motor setup data parameters.

9.5. Preventing unauthorized parameter editing

Locking Parameter Access

Steps to lock parameter access.

Unlocking Parameter Access

Steps to unlock parameter access.

10. Serial communications

Modbus RTU Communications

Information on Modbus RTU communication protocol.

Modbus Control & Monitoring Registers

List of accessible Modbus registers for control and monitoring.

11. Technical Data

Input;Output Current ratings and fuses

Current ratings, fuse recommendations, and cable sizes.

12. Appendix: Permanent magnet synchronous motors (PMSMs)

PMSM Motor nameplate data entry

Key parameters for PMSM motor setup.

PMSM Motor Auto-tune

Procedure for performing PMSM motor auto-tune.

Troubleshooting

Common issues and corrective actions for PMSM motors.

13. Troubleshooting

Fault messages

List of fault codes, descriptions, and corrective actions.

ABB ACS255 Specifications

General IconGeneral
Product TypeAC Drive
TypeACS255
Communication OptionsModbus RTU
Protection ClassIP20
IP RatingIP20
Overload Capacity150% for 60 seconds
BrakingIntegrated braking chopper
AltitudeUp to 1000 m without derating
Input Voltage200 to 480 V
Supply Voltage200 to 480 V
Frequency range48 to 63 Hz
Control MethodScalar control
CommunicationModbus RTU
Operating temperature-10°C to +50°C
Storage temperature-40 to +70 °C
Humidity5 to 95% non-condensing