62 Actual signals and parameters
9904 MOTOR CTRL
MODE
Selects the motor control modes.
WARNING! The VECTOR:TORQ motor
control mode is not functional for solar mode.
SCALAR:
FREQ
VECTOR:
SPEED
Vector control mode without sensor.
Reference 1 = Reference speed in RPM
Reference 2 = Reference speed in %. Absolute
maximum speed is 100%, which is equal to the value
in 2002 MAXIMUM SPEED (or 2001 MINIMUM
SPEED if the absolute value of the minimum speed is
greater than maximum speed).
1
SCALAR: FREQ Scalar control mode.
Reference 1 = Reference frequency in Hz.
Reference 2 = Reference frequency as %. The
absolute maximum frequency is 100%, equal to the
value in 20.08 MAXIMUM FREQ (or 20.07 MINIMUM
FREQ if the absolute value of the minimum speed is
greater than the maximum speed).
3
All parameters
No. Name/
Value
Description Def/ FbEq