Parameters 243
26.09 Maximum torque ref Defines the maximum torque reference. Allows for local
limiting of the torque reference before it is passed on to the
torque ramp controller. For absolute torque limiting, refer to
parameter 30.20 Maximum torque 1.
300.0%
0.0 … 1000.0% Maximum torque reference. See par.
46.03
26.11 Torque ref1 source Selects torque reference source 1.
Two signal sources can be defined by this parameter and
26.12 Torque ref2 source. A digital source selected by 26.14
Torque ref1/2 selection can be used to switch between the two
sources, or a mathematical function (26.13 Torque ref1
function) applied to the two signals to create the reference.
Zero
Zero None. 0
AI1 scaled 12.12 AI1 scaled value (see page 161). 1
AI2 scaled 12.22 AI2 scaled value (see page 162). 2
FB A ref1 03.05 FB A reference 1 (see page 122). 4
FB A ref2 03.06 FB A reference 2 (see page 122). 5
EFB ref1 03.09 EFB reference 1 (see page 122). 8
EFB ref2 03.10 EFB reference 2 (see page 122). 9
DDCS ctrl ref1 03.11 DDCS controller ref 1 (see page 122). 10
DDCS ctrl ref2 03.12 DDCS controller ref 2 (see page 122). 11
M/F reference 1 03.13 M/F or D2D ref1 (see page 122). 12
M/F reference 2 03.14 M/F or D2D ref2 (see page 122). 13
Motor
potentiometer
22.80 Motor potentiometer ref act (output of the motor
potentiometer).
15
PID 40.01 Process PID output actual (output of the process PID
controller).
16
Control panel (ref
saved)
Control panel reference, with initial value from last-used panel
reference. See section Using the control panel as an external
control source (page 21).
18
Control panel (ref
copied)
Control panel reference, with initial value from previous
source or actual value. See section Using the control panel as
an external control source (page 21).
19
Other Source selection (see Terms and abbreviations on page 114). -
No. Name/Value Description Def/FbEq16
26.13
Ref1
26.14
1
0
MUL
SUB
ADD
MIN
MAX
26.11
0
AI
FB
26.12
26.72
26.70
26.71
…
Other
…
0
AI
FB
…
Other
…