Parameters 37
09.14 Fault word 1 Defines SPRS fault word 1. This parameter is read-only. -
09.15 Warning word 1 Defines SPRS warning word 1. This parameter is read-only. -
09.28 Drive reference
percentage [%]
Shows inverter reference before converting to equivalent
frequency.
0.0
0.0...300.0% Inverter reference. 1 = 1%
09.32 Actual speed
feedback
Shows actual speed measured by tachometer in counts. 0.0
0.0...10000.0 RPM Counter value. 1 = 1RPM
09.42 Mot pot reference
value
Shows speed reference value given as increase/decrease
push button for SPRS.
0
0...30000% Counts 1 = 1%
No. Name/Value Description Def/
FbEq16/32
Bit Name Description
0 Emergency stop 1 = Emergency stop fault active.
1 Max speed operation 1 = Max speed operation fault active.
2 Min speed operation 1 = Min speed operation fault active.
3 Rotor over voltage 1 = Rotor over voltage fault active.
4 Over current 1 = Over current fault active.
5 HT isolator trip 1 = HT isolator trip fault active due to non
availability of feedback.
6 Rotor circuit isolator trip 1 = Rotor circuit isolator trip fault active
due to non availability of feedback.
7 Trafo fault 1 = Trafo fault active due to non availability
of feedback.
8 App External fault 1 1 = App External fault 1 active due to non
availability of feedback.
9 App External fault 2 1 = App External fault 2 active due to non
availability of feedback.
10 Earth fault 1 = Earth fault active.
11 HT Breaker Fault 1 = HT Breaker Fault active due to non
availability of feedback.
12...15 Reserved
Bit Name Description
0 GRR contactor not open 1 = GRR contactor not open warning
command active due to non availability of
feedback.
1 SPRS contactor not close 1 = SPRS contactor not closed warning
command active due to non availability of
feedback.
2 Tacho feedback fail 1 = No tacho feedback warning command
active due to non availability of feedback.
3 SPRS ready 1 = SPRS ready for operation warning
command active.
4...15 Reserved