AquaMaster 3
Electromagnetic flowmeter 5 Specification
40 User Guide OI/FET2XX–EN Rev. E
AC-powered reduced bore meters – flow specifications
OIML Class 2 specification OIML Class 1 specification
Size Q4 Q3 Q(0.25%) Q2 Q1 RQ2 Q1
R
mm in.
m
3
/ h
(Ugal / min)
m
3
/ h
(Ugal / min)
m
3
/ h
(Ugal / min)
m
3
/ h
(Ugal / min)
m
3
/ h
(Ugal / min)
m
3
/ h
(Ugal / min)
m
3
/ h
(Ugal / min)
15
1
/2 5 (22) 4 (18) 0.11 (0.48) 0.010 (0.044) 0.006 (0.026) 630 0.016 (0.070) 0.010 (0.04) 400
20
3
/4 7.9 (35) 6.3 (28) 0.18 (0.79) 0.016 (0.070) 0.010 (0.044) 630 0.025 (0.11) 0.016 (0.070) 400
25 1 12.5 (55) 10 (44) 0.29 (1.27) 0.025 (0.11) 0.016 (0.070) 630 0.04 (0.176) 0.025 (0.11) 400
40* 1
1
/2 31 (138) 25 (110) 1.5 (6.6) 0.063 (0.28) 0.040 (0.176) 630 0.1 (0.44) 0.063 (0.28) 400
50* 2 50 (220) 40 (176) 1.5 (6.6) 0.1 (0.44) 0.063 (0.277) 630 0.16 (0.70) 0.1 (0.44) 400
65 2
1
/2 79 (247) 63 (277) 1.8 (6.2) 0.16 (0.7) 0.1 (0.44) 630 0.25 (1.10) 0.16 (0.70) 400
80* 3 125 (550) 100 (440) 3 (13.2) 0.3 (1.32) 0.16 (0.70) 630 0.4 (1.76) 0.25 (1.10) 400
100* 4 200 (880) 160 (700) 4.6 (20.25) 0.41 (1.8) 0.25 (1.10) 630 0.64 (2.82) 0.4 (1.76) 400
125 5 200 (880) 160 (700) 4.6 (20.25) 0.41 (1.8) 0.25 (1.10) 630 0.64 (2.82) 0.4 (1.76) 400
150* 6 500 (2200) 400 (1760) 11.4 (50.19) 1 (4) 0.63 (12.77) 630 1.6 (7.04) 1.0 (4.40) 400
200* 8 788 (3470) 630 (2770) 18 (79.25) 1.6 (7) 1.0 (4.40) 630 2.5 (11) 1.6 (7.04) 400
250* 10 1250 (5500) 1000 (4400) 29 (127.7) 2.5 (11) 1.6 (7.04) 630 4 (17.6) 2.5 (11) 400
300* 12 2000 (8810) 1600 (7040) 46 (202) 4.1 (18) 2.5 (11) 630 6.4 (28.18) 4 (17.6) 400
350 14 2000 (8810) 1600 (7040) 80 (352) 6.4 (28.18) 4 (17.6) 400 12.8 (56.35) 8 (35.22) 200
400 16 3125 (13760) 2500 (11007) 125 (550) 10 (44) 6.3 (27.73) 400 20 (88.05) 12.5 (55.03) 200
450 18 3125 (13760) 2500 (11007) 125 (550) 10 (44) 6.3 (27.73) 400 20 (88.05) 12.5 (55.03) 200
500 20 5000 (22010) 4000 (17610) 200 (880) 16 (70.44) 10 (44) 400 32 (140.9) 20 (88.05) 200
600 24 7875 (34760) 6300 (27740) 315 (1387) 25.2 (110.9) 15.8 (69.56) 400 50.4 (221.9) 31.5 (138.7) 200
* OIML R49 version available to Class 1 and Class 2
Note. Note. OIML R49–1 allows Class 1 only for meters with Q3 100 m
3
/ h. Meters outside this range were
tested to Class 1 accuracy and passed.