DCS500 Pin and Parameter list
A 73
FIELDBUS_PAR.13
Parameter of FIELDBUS-function block. (S12/16 ).
Fieldbus parameter with adapter specific function
PROFIBUS not used
AC31 not used
MODBUS not used
MODBUS+ GD In3 Stn 0 ... 64
CANopen not used
DeviceNet ABB DRIVES STOP M (0) COAST STOP
(1) RAMP STOP
4013 FB_P: I2 SC: 1 HL: 32767 LL: 0 D: 0 U: -
FIELDBUS_PAR.14
Parameter of FIELDBUS-function block. (S12/16 ).
Fieldbus parameter with adapter specific function
PROFIBUS not used
AC31 not used
MODBUS not used
MODBUS+ GD In3 Wrd 0 ... 31
CANopen not used
DeviceNet RAMP STOP LEVEL 0 20000
4014 FB_P: I2 SC: 1 HL: 32767 LL: 0 D: 0 U: -
FIELDBUS_PAR.15
Parameter of FIELDBUS-function block. (S12/16 ).
Fieldbus parameter with adapter specific function
PROFIBUS not used
AC31 not used
MODBUS not used
MODBUS+ not used
CANopen not used
DeviceNet NO. OF DATASETS 1 20
4015 FB_P: I2 SC: 1 HL: 32767 LL: 0 D: 0 U: -