83
3ADW000395R0100 DCS550 Quick guide edisf a
833ADW000395R0100 DCS550 Quick guide edisf a
Faults & Alarms / Diagnosis
LED
Alarm Word
Text on DCS550 panel,
DriveWindow Light and
DriveWindow
Definition
EN
Text in DCS550 Panel,
DriveWindow Light und
DriveWindow
Beschreibung
DE
Testo DCS550 Pannello,
DriveWindow Light e
DriveWindow
Descrizione
IT
Texto en el DCS550 Panel,
DriveWindow Light y
DriveWindow
Definición
SP
Texte dans la DCS550
Microconsole,
DriveWindow Light et
DriveWindow
Description
FR
A101 9.06 Bit 0 Off2ViaDI
Off2 (Emergency Off / Coast stop)
pending via binary input,
Off2 (10.08)
Off2ViaDI
Off2 (Notaus / Austrudeln) ist am
einem binären Eingang aktiv,
Off2 (10.08)
Off2ViaDI
Off2 (10.08)
Off2ViaDI
Configuración Entradas Digitales
(Emergency Off / Coast stop),
Off2 (10.08)
Off2ViaDI
Off2 (10.08)
A102 9.06 Bit 1 Off3ViaDI
Off3 (E-stop) pending via digital
input, E Stop (10.09)
Off3ViaDI
Off3 (Nothalt) ist am einem binären
Eingang aktiv, E Stop (10.09)
Off3ViaDI
E Stop (10.09)
Off3ViaDI
Configuración Entradas Digitales
(E- stop), E Stop (10.09)
Off3ViaDI
E Stop (10.09)
A103 9.06 Bit 2 DCBreakAck
DC-Breaker acknowledge missing,
DCBreakAck (10.23)
DCBreakAck
Ausgewählter Motor, Rückmeldung
Gleichstromschnellschalter fehlt,
DCBreakAck (10.23)
DCBreakAck
DCBreakAck (10.23)
DCBreakAck
Interruptor CC no reconocido,
DCBreakAck (10.23)
DCBreakAck
DCBreakAck (10.23)
A104 9.06 Bit 3 ConvOverTemp
Converter overtemperature,
MaxBridgeTemp (4.17), ConvFanAck
(10.20)
ConvOverTemp
Übertemperatur Stromrichter,
MaxBridgeTemp (4.17), ConvFanAck
(10.20)
ConvOverTemp
Sovratemperatura sezione di
potenza, MaxBridgeTemp (4.17),
ConvFanAck (10.20)
ConvOverTemp
Sobretemperatura en la sección
de potencia, MaxBridgeTemp
(4.17), ConvFanAck (10.20)
ConvOverTemp
Echauffement anormal du pont de
puissance, MaxBridgeTemp (4.17),
ConvFanAck (10.20)
A105 9.06 Bit 4 DynBrakeAck
Dynamic braking is still pending,
DynBrakeAck (10.22)
DynBrakeAck
Ausgewählter Motor,
Wiederstandsbremsung ist am
einem digitalen Eingang aktiv,
DynBrakeAck (10.22)
DynBrakeAck
DynBrakeAck (10.22)
DynBrakeAck
Falta configurar freno dinámico
via Entradas Digitales,
DynBrakeAck (10.22)
DynBrakeAck
DynBrakeAck (10.22)
A106 9.06 Bit 5 M1OverTemp
Motor measured overtemperature,
M1AlarmLimTemp (31.06)
M1OverTemp
Motor 1 gemessene
Übertemperatur,
M1AlarmLimTemp (31.06)
M1OverTemp
Motore 1 sovratemperatura,
M1AlarmLimTemp (31.06)
M1OverTemp
Motor 1 sobretemperatura,
M1AlarmLimTemp (31.06)
M1OverTemp
Moteur 1 echauffement anormal,
M1AlarmLimTemp (31.06)
A107 9.06 Bit 6 M1OverLoad
Motor calculated overload,
M1AlarmLimLoad (31.04)
M1OverLoad
Motor 1 berechnete Überlast,
M1AlarmLimLoad (31.04)
M1OverLoad
Motore 1 sovraccarico,
M1AlarmLimLoad (31.04)
M1OverLoad
Motor 1 sobrecarga,
M1AlarmLimLoad (31.04)
M1OverLoad
Moteur 1 surcharge,
M1AlarmLimLoad (31.04)
A111 9.06 Bit 10 MainsLowVolt
Mains low (under-) voltage (AC),
UnetMin1 (30.22)
MainsLowVolt
Netz-Unterspannung (AC),
UnetMin1 (30.22)
MainsLowVolt
Minima tensione di alimentazione
di rete (c.a.), UnetMin1 (30.22)
MainsLowVolt
Bajatension de red (C.A.),
UnetMin1 (30.22)
MainsLowVolt
Sous-tension réseau (AC),
UnetMin1 (30.22)
A113 9.06 Bit 12 COM8Com
SDCS-COM-8 com. loss,
Ch0ComLossCtrl (70.05),
Ch2ComLossCtrl (70.15)
COM8Com
Kommunikation zwischen SDCS-
COM-8 und übergeordneter
Steuerung bzw. Master-Follower
Verbindung, Ch0ComLossCtrl (70.05),
Ch2ComLossCtrl (70.15)
COM8Com
Ch0ComLossCtrl (70.05),
Ch2ComLossCtrl (70.15)
COM8Com
Pérdida comunicación en el lazo
SDCS COM-8, PLC y Maestro
Esclavo ,
Ch0ComLossCtrl (70.05),
Ch2ComLossCtrl (70.15)
COM8Com
Ch0ComLossCtrl (70.05),
Ch2ComLossCtrl (70.15)
A114 9.06 Bit 13 ArmCurDev
Armature current deviation,
MotCur (1.06), CurRefUsed (3.12)
ArmCurDev
Ankerstrom-Abweichung,
MotCur (1.06), CurRefUsed (3.12)
ArmCurDev
Deviazione corrente d’indotto,
MotCur (1.06), CurRefUsed (3.12)
ArmCurDev
Desviación corriente del inducido,
MotCur (1.06), CurRefUsed (3.12)
ArmCurDev
Écart de courant d’induit,
MotCur (1.06), CurRefUsed (3.12)
A115 9.06 Bit 14 TachoRange
Tacho range,
terminals X3:1 to X3:4 on SDCS-
CON-F
TachoRange
Ausgewählter Motor,
Überschreitung Tachobereich,
Klemmen X3:1 bis X3:4 on SDCS-
CON-F
TachoRange TachoRange
Rango de la taco erroneo en los
terminales X3:1 a X3:4 de la SDCS-
CON-F
TachoRange
Alarm list Alarmliste Allarme di lista Lista de alarmas Liste des alarmes