4
Safety instructions
3ADW000803R0101 DCS880 H4T (Tosa) manual en a
Safety instructions
What this chapter contains
This chapter contains the safety instructions you must follow when installing, operating and servicing
the drive/unit.
If ignored, physical injury or death may follow, or damage may occur to the drive/unit, the motor/load or
driven equipment. Read the safety instructions before you work on the unit.
To which products this chapter applies
The information is valid for the whole range of the product line DCS880, the converter modules DCS880-
S0x size H1 … H8, field exciter units DCF80x, Rebuild Kit DCS880-R00, etc.
Usage of warnings and notes
There are two types of safety instructions throughout this manual: warnings and notes.
Warnings caution you about conditions which can result in serious injury or death and/or damage to the
equipment, and advice on how to avoid the danger.
Notes draw attention to a particular condition or fact or give information on a subject.
The warning symbols are used as follows:
Dangerous voltage warning warns of high voltage which can cause physical injury or death
and/or damage to the equipment.
General danger warning warns about conditions, other than those caused by electricity,
which can result in physical injury or death and/or damage to the equipment.
Electrostatic sensitive devices warning
warns of electrostatic discharge which can
damage the equipment.
Installation and maintenance work
These warnings are intended for all who work on the drive/unit, motor/load cable or motor/load.
Ignoring the instructions can cause physical injury or death and/or damage to the equipment.
WARNING
Only qualified electricians are allowed to install and maintain the drive/unit!
Never work on the drive/unit, motor/load cable or motor/load when mains power is
applied.
Always ensure by measuring with a multimeter (impedance at least 1 M) that:
1. Voltage between drive/unit input phases U1, V1 and W1 and the frame is close
to 0 V.
2. Voltage between terminals C+ and D- and the frame is close to 0 V.
Do not work on the control cables when power is applied to the drive/unit or to the
external control circuits. Externally supplied control circuits may cause dangerous
voltages inside the drive/unit even when the mains
power on the drive/unit is switched
off.
Do not make any insulation resistance or voltage withstand tests on the drive/unit or
drive modules.
Isolate the motor/load cables from the drive/unit when testing the insulation
resistance or voltage withstand of the cables or the motor/load.
When reconnecting the motor/load cable, always check that the C+ and D- cables are
connected with the proper terminal.

Other manuals for ABB DCS880

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB DCS880 and is the answer not in the manual?

ABB DCS880 Specifications

General IconGeneral
Control TypeDigital
Voltage RangeUp to 1200 V DC
Control PrincipleField-oriented control
Field SupplyIntegrated
Communication ProtocolsCANopen
CoolingAir
Protection ClassIP00, IP20, IP21, IP54
Protection FeaturesOvervoltage, overtemperature, short circuit, earth fault
Rated Voltage230 to 1200 V DC
Supply Voltage380 ... 690 V AC
Input Voltage Range230 to 690 V AC
Control ModeSpeed, Torque

Related product manuals