- 26 -
cr09_02
Parameter InformationValue
Fill On FALSE
Burnback On FALSE
Burnback Voltage On FALSE
Rollback On FALSE
Rollback Wirefeed On FALSE
Autoinhibit On FALSE
Welder Robot TRUE
Heat As Time FALSE
Override On FALSE
Schedport Type 3
Arc Preset 0.2
Ignition Timeout 2
Weld Off Timeout 10
Time to feed 15mm wire 0.33
ARC_EQUIPMENT_DIGITAL_INPUTS
Parameter Value Information
Name MIG1
ManFeedInput TRUE
WeldInhib TRUE
WeaveInhib TRUE
TrackInhib TRUE
SupervInhib TRUE
StopProc TRUE
ArcEst diArcEstablished
ArcEstLabel TRUE
ArcEst2 TRUE
ArcEstLabel2 TRUE
WeldOk diWeldingActive
WeldOkLabel TRUE
VoltageOk TRUE
VoltageOkLabel TRUE
CurrentOK TRUE
CurrentOKLabel TRUE
WaterOk siWater
WaterOkLabel TRUE
WirefeedOk siWire
WirefeedOkLabel TRUE
GasOK siGas
GasOkLabel TRUE

Related product manuals