- 31 -
cr09_02
Cross reference Anybus
This table lists examples of cross references for W8
2
Anybus.
ABB W82
Signal Name Type Adress Signal Name Type Byte Bit
doWeldOn OUT 0 Weld On IN 0 0
doQuickStop OUT 1 Quick Stop IN 0 1
doEmergencyStop OUT 2 Emerg. Stop IN 0 2
doWireFeedOn OUT 3 Inching IN 0 3
doGasPurgeOn OUT 4 Gas Purge IN 0 4
doAirCleanOn OUT 5 Clean IN 0 5
doWireFeedReverseOn OUT 6 Inch Reverse IN 0 6
doRemoteActiveOn OUT 7 Remote Active IN 0 7
doWireFeeder1On OUT 8 Wire Feed 1 IN 1 0
doWireFeeder2On OUT 9 Wire Feed 2 IN 1 1
doWireFeeder3On OUT 10 Wire Feed 1 IN 1 2
doWireFeeder4On OUT 11 Wire Feed 4 IN 1 3
doAnalogOn OUT 12 Analog Active IN 1 4
doReleaseWireOn OUT 14 Release Wire IN 1 6
doTouchSenseOn OUT 15 Touch Sense IN 1 7
goWeldDataNumber OUT(GO) 1623 Weld Data Number IN 2 07
aoWeldVoltageRef OUT(AO) 6479 Voltage Low Byte IN 8 07
aoWeldVoltageRef Voltage High Byte IN 9 07
aoWireFeedSpeedRef OUT(AO) 8095 Wire Feed Speed Low Byte IN 10 07
aoWireFeedSpeedRef Wire Feed Speed High Byte IN 11 07
diWeldingActive IN 0 Weld Busy OUT 0 0
diArcEstablished IN 1 Arc Acknowledge OUT 0 1
diTouchSenseResponse IN 2 TouchSense Response OUT 0 2
diRemoteActive IN 3 Remote Active OUT 0 3
diWireFeeder1Active IN 4 WFU 1 Active OUT 0 4
diWireFeeder2Active IN 5 WFU 2 Active OUT 0 5
diWireFeeder3Active IN 6 WFU 3 Active OUT 0 6
diWireFeeder4Active IN 7 WFU 4 Active OUT 0 7
diErrorType1 IN 8 Error Type 1 OUT 1 0
diErrorType2 IN 9 Error Type 2 OUT 1 1
diErrorType3 IN 10 Error Type 3 OUT 1 2
diErrorType4 IN 11 Error Type 4 OUT 1 3
diErrorType5 IN 12 Error Type 5 OUT 1 4
diErrorType6 IN 13 Error Type 6 OUT 1 5
diErrorType7 IN 14 Error Type 7 OUT 1 6
diErrorType8 IN 15 Error Type 8 OUT 1 7
diWDUErrorActive IN 16 Error WDU OUT 2 0