16
000430CG-F
2 - Characteristics
Characteristics and technical data
Table: Technical Data
PVI-10.0-TL-OUTD PVI-12.5-TL-OUTD
Input
Absolute Maximum Input Voltage (Vmax,abs) 900 V
Rated Input Voltage (Vdcr) 580 V
Input start-up voltage (Vstart) 360 V (adj. 250...500 V)
Input operating interval (Vdcmin...Vdcmax) 0.7 x Vstart...850 V (min 200 V)
Input Nominal Power(Pdcr) 10300 W 12800 W
Number of Independent MPPT 2
Maximum input power for Each MPPT
(PMPPTmax)
6500 W 8000 W
Input voltage interval (VMPPTmin ... VMPPTmax)
to Pacr (parallel MPPT conguration)
300…750 V 360...750 V
DC Power limiting for each MPPT
with Independent MPPT Conguration to Pacr,
maximum unbalance example
6500 W [380V≤VMPPT≤750V]
other channel:
Pdcr-6500W [225V≤VMPPT≤750V]
8000 W [445V≤VMPPT≤750V]
other channel:
Pdcr-8000W [270V≤VMPPT≤750V]
Maximum DC Input Current (Idcmax) / for each
MPPT (IMPPTmax)
34.0 A / 17.0 A 36.0 A / 18.0 A
Maximum Return current (AC side vs DC side) Negligible
Number of DC Connection Pairs in Input for
each MPPT
2
DC Input Connector type (components indica-
ted or equivalents)
Quick Fit PV Connector
(5)
Type of photovoltaic panels that can be con-
nected at input according to IEC 61730
Class A
Input protection
Reverse Polarity Protection
Inverter protection only, from limited current source, for standard and
-S versions, and for -FS version when max 2 strings are connected
Input Overvoltage protection for each MPPT -
Varistors
Yes
Maximum short-circuit current for each MPPT 22.0 A
Insulation Check Complying with the local standard
DC Disconnect Switch rating ( -S Version) Max. 32.0 A / 1000 V
Fuse Rating (-FS Version) gPV / 1000 V / Max. 20.0 A