2TLC172015M0201, rev. D www.abb.com/lowvoltage
Default setting
Switch Status Function
8
OFF Manual reset Single break if SB/DB selected
ON Automatic reset Double break if SB/DB selected
7
OFF
Refer to Coding section for further information
ON
6
OFF EDM function disabled
ON EDM function enabled
5 + 4
1
4 5 Muting and special functions
OFF OFF Muting T with time limit, 0.2 s allowed drop
2
OFF ON Muting L with time limit, 0.2 s allowed drop
2
ON OFF Muting X without time limit
6
, 0.2 s allowed drop
2
ON ON Special function with switches 1, 2 and 3
Light curtain specic settings:
Muting maps when muting T, L or X
are selected on switches 4 and 5
3
Special functions selection when
switches 4 and 5 are both ON
4
3+2+1
1 2 3
OFF OFF OFF Muting all beams Blanking ± 1 beam with T muting
OFF OFF ON Muting on module 1, 2, 3 and 4 Blanking +1/-0 beam with T muting
OFF ON OFF Muting on module 1, 2 and 3 Blanking ± 0 beam with T muting
OFF ON ON Muting on module 1 and 2 Blanking ± 1 beam with L muting
ON OFF OFF Muting on module 1 Blanking +1/-0 beam with L muting
ON OFF ON Muting on module 2 Blanking ± 0 beam with L muting
ON ON OFF Muting on module 3 Pre-Reset mode
ON ON ON Muting on module 4 Single break/double break, Switch 8
1 2 3 4 5 6 7 8
OFF
ON
1 2 3 4 5 6 7 8
OFF
ON
Switch no. 8 in ON position
4.4 Setting up of Internal Change-Over Switches Receiver
• Disconnect the power supply to the unit and open the small lid in the bottom cap (with the M12 connec-
tor) so that the two change-over switches become visible.
• The change-over switches may be adjusted to the desirable position with a small, suitable screwdriver.
NB! Make sure to always set switches in both banks to the same position (except switch 7 on the
receiver).