5
www.abb.com/lowvoltage 2TLC172015M0201, rev. D
Type 4 FII-4-14-zzzz FII-4-30-zzzz FII-4-K4-zzzz FII-4-K3-800 FII-4-K2-500 FII-4-K4-
zzzz D
FII-4-K3-800 D FII-4-K2-500 D FII-4-K2C-
zzzz
FII-4-K2C-800 FII-4-K1C-500
Resolution 14 30
Beam distance 300 400 400 500 300 400 400 500 300 400 400 500
Height (mm=zzzz)
See 5.7
150
300
450
600
750
900
1050
1200
1350
1500
1650
1800
1950
2100
2250
2400
150
300
450
600
750
900
1050
1200
1350
1500
1650
1800
1950
2100
2250
2400
900 1200 800 500 900 1200 800 500 900 1200 800 500
Range (m)
SR
LR
0.2-3
3-6
0.2-7
7-14
0.5-20
20-40
0.5-20
20-40
0.5-20
20-40
0.5-20
20-40
0.5-20
20-40
0.5-20
20-40
0.5-7 0.5-8 0.5-12
Reaction time off (ms) See 5.7 See 5.7 13 13 13 13 13 13 13 13 13
Reaction time on (ms) See 5.7 See 5.7 142 142 142 142 142 142 142 142 142
Manual reset ● ● ● ● ● ● ● ● ● ● ●
Automatic reset ● ● ● ● ● ● ● ● ● ● ●
Pre reset ● ● ● ● ● ● ● ● ● ● ●
Muting inputs ● ● ● ● ● ● ● ● ● ● ●
Muting lamp supervision ● ● ● ● ● ● ● ● ● ● ●
Override ● ● ● ● ● ● ● ● ● ● ●
Muting T / L / X ● / ● / ● ● / ● / ● ● / ● / ● ● / ● / ● ● / ● / ● ● / ● / ● ● / ● / ● ● / ● / ● ● / ● / ● ● / ● / ● ● / ● / ●
Blanking 3 types ● / ● / ● ● / ● / ● - / - / - - / - / - - / - / - - / - / - - / - / - - / - / - - / - / - - / - / - - / - / -
Single / Double break ● / ● ● / ● - / - - / - - / - - / - - / - - / - - / - - / - - / -
EDM ● ● ● ● ● ● ● ● ● ● ●
Dyn. Adaption to
Vital / Pluto
¤ ¤ ¤ ¤ ¤ ¤ ¤ ¤ ¤ ¤ ¤
● Standard ¤ With Tina 10A / 10B / 10C or FMC-Tina
NB!
For ordering data and article number see 5.7.
For more information see our home page.
1 System Overview and Applications
Summary - Focus II light curtain/grid, Type 4 (FII-4-)