EasyManua.ls Logo

ABB Focus II FII-4-14 Series - 24 Test Procedure Log

ABB Focus II FII-4-14 Series
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
58
2TLC172015M0201, rev. D www.abb.com/lowvoltage
24 Test procedure log
Check point Condition Comments
Disable the guarded machine. Apply
power to the Focus II system, check
that LED 1 and 3 are lit on the
receiver.
£ Pass
£ Fail
Visually inspect the machine to
ensure that access to the hazardous
area is only through the Focus II
system.
£ Pass
£ Fail
Verify that the mounting distance of
the Focus II system is equal to or
greater than the minimum distance.
See 3.3 or 3.4
£ Pass
£ Fail
Check for signs of damage in the
Focus II system installation, the
cables and wiring. If something are
damaged, secure the machine and
report.
£ Pass
£ Fail
Interrupt the Focus II system
detection zone with the supplied test
tool. See 16
£ Pass
£ Fail
Start the machine. Check that the
machine stops when the test tool is
inserted to the detection zone, and
it is not possible to restart when the
test tool is in the detection zone.
£ Pass
£ Fail
Verify that the safety system is
stopping the machine fast enough
otherwise adjust or increase the
distance.
£ Pass
£ Fail
If the safety devices on the machine
fails any of these tests, secure
machine and report.
£ Pass
£ Fail
Date and Signature:
_______________ __________________________________________________