23
www.abb.com/lowvoltage 2TLC172015M0201, rev. D
5.3 Connection Example, muting unit to safety relay
5.4 Connection Example, Vital / Pluto with Tina units
A B C D
*)
Test/
Reset
*)
A
*)
Test/
Reset
L1
*)
+ -
+ -
B C D
1
2
3
4
5
Brown
+24VDC
Blue
0V
Brown
+24VDC
Blue
0V
1
2
3
4
5
6
7
8
White
Test / Reset
Green
Yellow
OSSD 1 (RL 500mA max.)
OSSD 2 (RL 500mA max.)
Muting Lamp
(220Ω / 3W)
Grey
Pink
Red
Screen
Ground
Screen
Ground
1
13 14 42 24 23 33 41 34 Y24 Y14
In
1&2
14 13 23 24
Type: RT6
A1 A2
Test/Auto
S24
ABB
S34 S13 S14 S23 S53 Y13
Reset
X1
X4
S13
Type: RT9
A1 A2
ABB
S14
S34 S44 S24
- +
Y14
Test/Auto
Reset
X1 X4
C
D
B
B
A
A
White
Black
Grey
2
2
1
2
3
4
5
1
2
3
4
5
6
7
8
1
2
3
4
5
1
2
3
4
5
6
7
8
Transmitter Receiver
Muting unit Muting unit
M12 Cable
L1
+ -
FMC-1 Tina
FMC-2 Tina
Tina-10A
Tina-10B
Tina-10C
+24VDC 0V
L1
1
2
3
4
5
Brown
+24VDC
Blue
0V
Brown
Blue
1
2
3
4
5
6
7
8
White
Green
Yellow
Grey
Pink
Red
Screen
Ground
14 13 23 24
S1
Type: Vital 1
A1 A2
ABB
B1
T1 B2 R1
- +
Y14
Test/Auto
Reset
X1 X4
2
1
White
Black
Grey
2
*)
Test/
Reset
Info
1
2
3
4
5
5 Grey
3 Blue
4 Black
2 White
1 Brown
*)
Transmitter Receiver
M12 Cable
Type: Pluto
+24V 0V
ABB
IQ10
I0
Reset
Info
1 2 3 4 5
Q0 Q1
IQ11
4
2
5
3
1

Table of Contents