14 Receiver LED Information
Normal operation
# LED indication Name of LED Colour
1 Green
2 Yellow
3 Green
4 Red
5 Yellow
1 2 3 4 5 Description
1
OSSD on
2
OSSD off
3
Waiting for Reset
4
Alignment mode - best optical alignment
5
Short circuit on output
Pre-reset:
6
Waiting for reset
7
º
Pre-reset button pushed. Waiting for reset. 1 ash/sec.
Blanking:
8
º
Floating blanking active
9
º
Floating blanking active, object in protective eld
Single/double break:
10
º
Waiting for manual restart of single/double break function sequence
after power on or after interruption of the protective eld while the
machine is working. 2 ashes/sec.
11
º
Normal operation of single/double break function (load/unload).
3 ashes/sec.
12
º
Normal operation of single/double break function (machine operation).
3 ashes/sec.