ActionCauseNameCode
(hex)
Warnings
1. Make sure that the
motor has sufficient
cooling.
2. Make sure that the
drive and the motor
are compatible with
each other.
3. Make sure that the
motor is not
overloaded.
4. Make sure that the
drive parameter
settings are correct.
5. Examine the wiring of
the temperature
sensor. If necessary,
repair the wiring.
6. Measure the
resistance of the
sensor. If necessary,
replace the sensor.
The FPTC module in
option slot 1 has activated
a motor temperature
warning in the XWRN input
(non-safety related).
1. Motor temperature is
too high, or
2. the thermistor is
short-circuited or
disconnected.
Motor
temperature
1
1)
A497
The FPTC module in
option slot 2 has activated
a motor temperature
warning in the XWRN input
(non-safety related). See
A497.
Motor
temperature
2
1)
A498
The FPTC module in
option slot 3 has activated
a motor temperature
warning in the XWRN input
(non-safety related). See
A497.
Motor
temperature
3
1)
A499
1)
Editable message text
For the fault and warning messages of the FSO module, see the FSO
module user’s manual.
Fault tracing 73