Switching to operator menu
The operator menu can be used to display diagnostics
information and select which operator pages to display.
1 Press
to switch to the operator menu
2 Press
or to select a submenu
3 Press
to confirm your selection
Menu Description
.../ Operator Menu Error / Alarm of the electronics
Diagnostics Error / Alarm of the sensor
 
“Diagnostic History.
 Select the operator page to displayed
 Select the operator page to displayed
 Select the operator page to displayed
Signals View Error / Alarm due to the present operating
conditions
Area Description
Electronics Error / Alarm of the electronics
Sensor Error / Alarm of the sensor
Status Alarm due to the present device status
Configuration Error / Alarm due to the present operating
conditions
Invoking the error description
In case of an error, a message consisting of an icon and text
appears at the bottom of the process display. The displayed
text indicates where the error has occurred.
1 Press
to switch to the operator menu
2 Press or to navigate to select a submenu
3 Press
to confirm your selection
The first line indicates where the error occurred
The second line shows the unique id.
The next lines give a brief description of the error and Its
remedy
Switching to the configuration level parameter entry
The device parameters can be displayed and changed on the
configuration level
1 Press
to switch to the configuration menu
2 Press or to select an access level
3 Press
to confirm your selection
IMPORTANT NOTE
There are four access levels as follows:
Read Only” level disables all entries. No parameter can
be modified
Standard” level can edit some parameters
“Advanced” level can edit all parameters
Service” level is reserved for ABB technician access
Passwords can be defined for the “Standard” and
Advanced” levels
Document your password so that it can be retrieved
later.
4 Enter the corresponding password
5 Press
to switch to the information level. The HMI display
now indicates the first menu item at the configuration level
6 Press
or to select a menu
7 Press
to confirm your selection

Table of Contents