24 2TLC172011M0205_B
For more information about the configuration data see the gateway manual.
dnet_gw> cs
Input Assembly Instance :
0 : Status Only [100]
1 : Data Only [101]
2 : Status/Data [102]
Select [1] : 1
Output Assembly Instance :
0 : No Data [112]
1 : To Pluto Data [113]
Select [1] : 1
Expected data from PLUTO 00 [Y] ? YES
Expected data from PLUTO 01 [N] ? YES
Expected data from PLUTO 02 [N] ? YES
Expected data from PLUTO 03 [N] ? YES
Expected data from PLUTO 04 [N] ? NO
Expected data from PLUTO 05 [N] ? NO
Expected data from PLUTO 06 [N] ? NO
Expected data from PLUTO 07 [N] ? NO
Expected data from PLUTO 08 [N] ? NO
Expected data from PLUTO 09 [N] ? NO
Expected data from PLUTO 10 [N] ? NO
Expected data from PLUTO 11 [N] ? NO
Expected data from PLUTO 12 [N] ? NO
Expected data from PLUTO 13 [N] ? NO
Expected data from PLUTO 14 [N] ? NO
Expected data from PLUTO 15 [N] ? NO
Expected data from PLUTO 16 [N] ? NO
Expected data from PLUTO 17 [N] ? NO
Expected data from PLUTO 18 [N] ? NO
Expected data from PLUTO 19 [N] ? NO
Expected data from PLUTO 20 [N] ? NO
Expected data from PLUTO 21 [N] ? NO
Expected data from PLUTO 22 [N] ? NO
Expected data from PLUTO 23 [N] ? NO
Expected data from PLUTO 24 [N] ? NO
Expected data from PLUTO 25 [N] ? NO
Expected data from PLUTO 26 [N] ? NO
Expected data from PLUTO 27 [N] ? NO
Expected data from PLUTO 28 [N] ? NO
Expected data from PLUTO 29 [N] ? NO
Expected data from PLUTO 30 [N] ? YES
Expected data from PLUTO 31 [N] ? YES
Enable To PLUTO package 0 [Y] ? YES
Enable To PLUTO package 1 [Y] ? YES
Enable To PLUTO package 2 [Y] ? YES
Enable To PLUTO package 3 [Y] ? YES
To PLUTO Timeout [256 ms] : 1000
Save the new configuration [y/n] YES
dnet_gw>