143Maintenance
EN
8.4.2 Replacing of the top fan section
Procedure for replacing the top fan sections:
Open the DC disconnect switches (19).
Open any AC disconnect switch downstream of the inverter or the AC disconnect switch (09) (only on
-S2, -SX2 model).
WARNING – B Do not open the front wiring box cover (07) or the front power module cover (06).
WARNING – B Wait the internal capacitors to be discharged (the discharge time of the stored
energy is indicated on the regulatory label), and check that fans are completely stopped.
Remove the 2 screws located on fan section.
Tilt the fan section as shown in the picture.
Pull out the fan section.
Disconnect the 2 fan connectors.
Take the new fan section and connect the 2 fan connectors. During this phase pay attenction to connect
the fan to the correspondent cable; on each fan cable coming from the power module are applied labels
that indicates the fans number (from FAN1 to FAN5).
Place the new fan section following the previous steps in reverse way.
Screw the 2 fastening screws previosly removed.
PVS

Table of Contents

Other manuals for ABB PVS-175-TL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB PVS-175-TL and is the answer not in the manual?

ABB PVS-175-TL Specifications

General IconGeneral
BrandABB
ModelPVS-175-TL
CategoryInverter
LanguageEnglish

Related product manuals