Operation Manual / TPL65VA32/33
Maintenance
5
Cleaning the compressor during
operation
5.3
Page 63
© Copyright 2015 ABB. All rights reserved.
September 2015 HZTL2464_EN Revision C
Wet cleaning using external water-pressure vessel (XC3)
Operating state prerequisites for compressor cleaning with XC3
NOTICE
To be able to carry out a satisfactory cleaning process which has been
tested and is recommended by ABB Turbo Systems, the following
prerequisites must be fulfilled:
Engine load 50 ... 85%
Start of cleaning cycle in accordance with following description for
wet cleaning operation with XC3.
Compressor wet cleaning procedure with XC3
It is mandatory to fulfil the operating condition prerequisites before
cleaning compressors with XC3.
Remove the sealing plug (X).
Fill the vessel with the required volume of clean water (see the
Table
of cleaning parameters
).
5.3.2
Operating the water
pressure vessel

Table of Contents