VortexMaster FSV430, FSV450 SwirlMaster FSS430, FSS450 | CI/FSV/FSS/430/450-EN  Rev. G  59 
 
 
7.2.3  Switching to the information level (operator menu) 
On the information level, the operator menu can be used to 
display diagnostic information and choose which operator 
pages to display. 
 
Process display 
 
 
 
 
 
 
 
 
1.  Open the Operator Menu using  . 
 
Operator Menu  
 
 
Diagnostics 
Operator Page 1 
Operator Page 2 
Back  Select 
 
2.  Select the desired submenu using   /  . 
3.  Confirm the selection with  . 
 
Menu Description 
… / Operator Menu 
Diagnostics  Selection of sub-menu "Diagnostics"; see also 
chapter "Error messages on the LCD display" 
on page 60. 
Operator Page 1 ... n  Selection of operator page to be displayed. 
Autoscroll When Autoscroll is activated, automatic 
switching of the operator pages is initiated on 
the process screen. 
Signal view  Selection of submenu "Signal view" (only for 
service purposes). 
 
 
 
7.2.4  Switching to the configuration level 
(parameterization) 
The device parameters can be displayed and changed on the 
configuration level. 
 
Process display 
 
 
 
 
 
 
 
 
1.  Use   to switch to the configuration level. 
 
ccess Level 
 
 
Read Only 
Standard 
Service 
Back  Select 
 
2.  Select the desired level of access using   /  . 
3.  Confirm the selection with  . 
 
NOTICE
  
There are three levels of access. A password can be defined 
for level "Standard".  
There is no factory default password. 
 
Access Level  Description 
Read Only  All parameters are locked. Parameters are read 
only and cannot be modified. 
Standard  All the parameters can be altered. 
Service  Only Customer Service has access to the Service 
menu.