EasyManua.ls Logo

Abbott FreeStyle Precision H User Manual

Abbott FreeStyle Precision H
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Users Manual
Manual del usuario
Blood Glucose and Ketone Monitoring System
Sistema de monitoreo de glucosa y cetonas en sangre

Table of Contents

Questions and Answers:

Abbott FreeStyle Precision H Specifications

General IconGeneral
Sample Size0.6 µL
Test Time5 seconds
DisplayLCD
Battery LifeApproximately 1000 tests
Measurement Range20-500 mg/dL
MemoryUp to 450 results
BatteryCR2032 lithium battery
Operating Conditions10°C to 40°C (50°F to 104°F); 10% to 90% relative humidity
Storage Conditions-20°C to 60°C, 5% to 95% RH

Summary

Intended Use

How the System Works

Monitoring System Kit Contents

Lists the components included in the monitoring system kit and items not included.

Setting Up the Meter

Enter Setup Mode

Instructions on how to enter the meter's setup mode using the device buttons.

Beeper Settings

Details on how to configure and understand the meter's beeper sounds.

Setting Time

Instructions for setting the current time on the meter.

Setting Date

Instructions for setting the current date on the meter.

Time Format Settings

How to select between 12-hour and 24-hour time formats.

Date Format Settings

How to select between Month-Day and Day.Month date formats.

Measurement Units

Explains the available measurement units (mg/dL, mmol/L) and their setting.

Preparing the Meter for Glucose Testing

Important Testing Notes for Glucose

Crucial guidelines for using test strips and handling samples for glucose tests.

Calibration for Glucose Testing

Explains the need for meter calibration for accurate glucose readings.

Calibrating the Meter for Glucose Testing

Step-by-step guide on how to calibrate the meter using the calibrator.

Confirming the LOT Number

Procedure to verify that the LOT number matches between meter and test strips.

Recalling the LOT Number

How to check the meter's calibration status and LOT number.

Testing Blood Glucose

Important Testing Notes for Glucose

Crucial guidelines for using test strips and handling samples for glucose tests.

Test Site for Glucose

Guidance on selecting the appropriate site for obtaining a blood sample.

Performing a Blood Glucose Test

Detailed steps on how to conduct a blood glucose test using the meter.

Obtain a Blood Sample

Instructions on how to obtain a blood sample using a lancing device.

Apply Blood to the Test Strip

Guidance on applying the blood sample correctly to the test strip.

View and Save Glucose Results

How to view the blood glucose test result and how it's stored.

Turn Off the Meter

Procedure for turning off the meter after completing a test.

Understanding Blood Glucose Test Results

Low and High Blood Glucose Results

Explanation of 'LO' and 'HI' readings and their implications.

High Blood Glucose Indicators

Interpreting 'KETONES?' and 'HI' displays for high glucose levels.

Preparing the Meter for Ketone Testing

Calibration for Ketone Testing

Explains the need for meter calibration for accurate ketone readings.

Calibrating the Meter for Ketone Testing

Step-by-step guide on how to calibrate the meter for ketone testing.

Confirming the LOT/CODE Number for Ketones

Procedure to verify LOT/CODE match for ketone test strip calibration.

Recalling the LOT/CODE Number for Ketones

How to check the meter's ketone calibration status and LOT/CODE number.

Testing Blood Ketone

Important Testing Notes for Ketones

Crucial guidelines for using test strips and handling samples for ketone tests.

Test Site for Ketone Testing

Guidance on selecting the appropriate site for obtaining a blood sample.

Performing a Blood Ketone Test

Detailed steps on how to conduct a blood ketone test using the meter.

Obtain a Blood Sample for Ketones

Instructions on obtaining a blood sample for ketone level measurement.

Apply Blood to the Ketone Test Strip

Guidance on applying the blood sample correctly to the ketone test strip.

View and Save Ketone Results

How to view the blood ketone test result and how it's stored.

Turn Off the Meter

Procedure for turning off the meter after completing a test.

Understanding Blood Ketone Test Results

High Blood Ketone Results

Interpreting high blood ketone readings and potential medical implications.

Interpreting High Ketone Levels

Details on high blood ketone levels and when to contact a physician.

MediSense Glucose and Ketone Control Solutions

Important Control Solution Testing Notes

Key guidelines for performing control solution tests correctly.

Performing a Control Solution Test

Apply Control Solution to Test Strip

Guidance on applying control solution correctly to the test strip.

View Control Solution Results

How to view the control solution test result and where it's stored.

Turn Off the Meter

Procedure for turning off the meter after completing a test.

Managing Results

Viewing Test Results in Memory

Instructions on how to access and review stored test results.

Understanding Result Types

Explains symbols indicating blood glucose, ketone, and control solution results.

Reviewing Previous Results

Steps to navigate through and review past test results in memory.

Viewing Blood Glucose Averages

Viewing 14 and 30-Day Averages

Instructions for viewing 14-day and 30-day average glucose readings.

Transferring Results to a Computer

Error Messages

Temperature and Meter Errors (E-1, E-2)

Troubleshooting for temperature-related errors and general meter errors.

Test Strip and Calibration Errors (E-4, E-5, E-6, E-7)

Troubleshooting for errors related to test strips and calibration.

Meter and Recognition Errors (E-8, E-9)

Troubleshooting for meter errors and unrecognized test strips.

Troubleshooting Common Issues

Meter Not Entering Test Mode

Steps to take if the meter does not enter test mode after inserting a strip.

Blood Sample Application Issues

Resolving issues with blood sample size or application timing.

Maintaining the Meter

Replacing the Battery

Guide on how to replace the meter's battery when it is low or depleted.

Battery Replacement Procedure

Detailed steps for inserting a new battery and powering on the meter.

Cleaning the Meter

Instructions on how to clean the exterior of the meter safely.

Specifications

Meter Functions and Ranges

Details on meter functions like memory, averaging, and assay methods.

Operating Range and Conditions

Information on meter operating temperature, humidity, and altitude.

Warranty Statement

Limited Warranty Terms

Specifies the duration, coverage, and limitations of the meter's warranty.

Limitation of Liability

Outlines Abbott's liability limits for meter use and performance.

Related product manuals