Installation and Operation Manual
SCL/SCM Series
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Questions and Answers

  • J
    jeffreywallaceAug 13, 2025
    Why am I getting a High DC Bus Voltage Fault on my AC Tech DC Drives?
    • D
      Dr. Jennifer Adams MDAug 13, 2025
      A high DC bus voltage fault in AC Tech DC Drives can occur due to several reasons: the line voltage might be too high, the deceleration rate might be too fast, or there could be an overhauling load. For fast deceleration or overhauling loads, dynamic braking may be required.
  • M
    michaela71Aug 16, 2025
    What to do if AC Tech SL205S DC Drives show Incompatibility Fault?
    • V
      valerie09Aug 16, 2025
      If you're encountering an Incompatibility Fault with your AC Tech DC Drives, it means an EPM with an incompatible parameter version has been installed. You can either remove the EPM or perform a factory reset using Parameter 48 to change the parameter version of the EPM to match that of the drive.
  • J
    Johnny HowellAug 20, 2025
    How to resolve Control Fault on AC Tech DC Drives?
    • J
      Justin BartonAug 20, 2025
      A Control Fault in AC Tech DC Drives means that a blank EPM or an EPM with corrupted data has been installed. To resolve this, perform a factory reset using Parameter 48 - PROGRAM SELECTION.
  • M
    Monica KempAug 25, 2025
    What does External Fault mean on AC Tech SL205S?
    • B
      Bethany WestAug 25, 2025
      An External Fault in AC Tech DC Drives is triggered when one of the TB-13 terminals is set as an External Fault input and that terminal is open with respect to TB-11. Refer to Parameters 10, 11, and 12.
  • C
    Catherine WilliamsAug 27, 2025
    Why AC Tech SL205S DC Drives show Start Fault?
    • S
      Steven CooperAug 28, 2025
      A Start Fault in AC Tech DC Drives occurs when a start command was present when the drive was powered up. If START METHOD is set to NORMAL, you must wait 2 seconds after power-up to apply the Start command.
  • R
    Rebecca PattersonAug 31, 2025
    What causes Low DC Bus Voltage Fault in AC Tech SL205S DC Drives?
    • S
      Sandy GloverAug 31, 2025
      A Low DC Bus Voltage Fault in AC Tech DC Drives indicates that the line voltage is too low.
  • S
    Stephen SmithSep 4, 2025
    What does Dynamic Braking Fault mean in AC Tech DC Drives?
    • L
      Lauren Hoffman PhDSep 4, 2025
      A Dynamic Braking Fault in AC Tech DC Drives means that the drive has detected that the dynamic braking resistors are overheating.
  • T
    Timothy SanchezSep 7, 2025
    What does Data Fault mean in AC Tech DC Drives?
    • M
      Michael WarrenSep 8, 2025
      A Data Fault in AC Tech DC Drives means that user data and OEM defaults in the EPM are corrupted.

Summary

INSTALLATION

INPUT AC POWER REQUIREMENTS

Input Voltage Ratings

Specifies acceptable input voltage ranges and tolerances for different drive models.

Input Fusing Requirements

Details circuit breaker and fuse ratings for installation according to NEC and local codes.

Installation According to EMC Requirements

Guidelines for meeting Electromagnetic Compatibility (EMC) standards for installation.

POWER WIRING

Input and Output Wiring

Instructions for connecting input power and output motor wires, including conduit separation.

SCL;SCM POWER WIRING DIAGRAM

CONTROL WIRING

SCL;SCM CONTROL WIRING DIAGRAMS

INITIAL POWER UP AND MOTOR ROTATION

PROGRAMMING THE SCL;SCM DRIVE

Setting Values in Tenths of Units Above 100

How to set parameter values and speed in tenths of units, especially above 100.

Electronic Programming Module (EPM)

Description of the removable EPM for parameter storage and quick drive setup.

PARAMETER MENU

DESCRIPTION OF PARAMETERS

TROUBLESHOOTING

SCL;SCM DISPLAY MESSAGES

AC Tech SL205S Specifications

General IconGeneral
Input Voltage115/230V AC
Output Current5A
Enclosure TypeNEMA 1
Speed Regulation±1%
Operating Temperature0-45°C (32-113°F)