33 SM01P
04 RAMP WITH DC BRAKE: When a stop command is given, the drive will decelerate
the motor down to 0.2 Hz (at the rate set by Parameter 20 - DECELERATION TIME)
and then activate DC braking according to the settings of Parameters 21 - DC BRAKE
TIME and 22 - DC BRAKE VOLTAGE. This is used to bring the load to a final stop,
as the motor may still be turning slightly after the drive stops.
P05 STANDARD SPEED SOURCE
P05 selects the speed reference source when the drive is in STANDARD speed mode.
The following speed references can be selected:
01 KEYPAD: Use the and buttons to scroll to the desired speed.
02 PRESET SPEED #1: Drive will operate at the frequency set in Parameter 31.
03 0-10 VDC: Drive will respond to a 0-10 VDC signal wired to TB-5 (+) and TB-2 (-).
04 4-20 mA: Drive will respond to a 4-20 mA signal wired to TB-25 (+) and TB-2 (-).
P06 RELAY OUTPUT
P06 selects the status indication for the normally open relay output at TB-16 and TB-17:
01 NONE: Disables the relay output.
02 RUN: Closes upon a START command. Opens if the drive is in a STOP state, the
drive faults, or input power is removed. DC braking is considered a STOP state.
03 FAULT: Closes if there is no fault condition. Opens if the drive faults, or input power
is removed.
04 INVERSE FAULT: Closes if the drive faults. Opens if there is no fault condition.
05 FAULT LOCKOUT: Closes when input power is applied. Opens if three restart attempts
are unsuccessful, or if input power is removed.
06 AT SET SPEED: Closes if the drive is within + 0.5 Hz of the speed setpoint.
07 ABOVE PRESET SPEED #3: Closes if the output frequency exceeds PRESET
SPEED #3 (Parameter 33). Opens if the output frequency is equal to or less than
PRESET SPEED #3.
08 CURRENT LIMIT: Closes if the output current exceeds the CURRENT LIMIT setting.
Opens if the output current is equal to or less than CURRENT LIMIT (see Parameter
25).
09 AUTOMATIC SPEED MODE: Closes if an AUTOMATIC (terminal strip) speed
reference is active. Opens if a STANDARD (Parameter 5) speed reference is
active.
10 REVERSE: Closes when reverse rotation is active. Opens when forward rotation is
active (see Parameter 17 - ROTATION DIRECTION).
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AC Tech SM205 and is the answer not in the manual?

AC Tech SM205 Specifications

General IconGeneral
BrandAC Tech
ModelSM205
CategoryDC Drives
LanguageEnglish

Related product manuals