3-42 Machine Maintenance Procedures
4. Disconnect the eDP cable (G) from the LCD panel connector (F) (Figure 3-42).
Figure 3-42. eDP Connector
5. Remove the LCD panel from the LCD cover.
Make sure the eDP and camera cable is moved away from the device to avoid
damage during LCD Panel removal.
ID Size Torque Quantity Screw Type
D M2.0*2.5-I 2.0±0.2KGF/CM 4