S1200 Condential
3-3
No Symptom
Procedure
3 No Image
• Ensure the Signal Cable and Source work
(If you connect multiple sources at the same time, use the
“Source” button on the control panel to switch)
Ensure all connectors are securely connected and aren’t bro-
ken
• Check Main Board
• Check DMD Board
• Check Colour Wheel
• Check DMD Chip
• Check Engine Module
4 No Light On
Ensure all connectors are securely connected and aren’t
broken
• Check Lamp Module
• Check Lamp Driver
• Check LVPS
• Check Main Board
5 Mechanical Noise
• Check Colour Wheel
• Check Fan Module
6 Line Bar/Line Defect
• Check if the Main Board and the DMD Board are
assembled properly
• Check Main Board
• Check DMD Board
• Check DMD Chip
7 Image Flicker
• Do “Reset (All data)” of the OSD Menu
Ensure that the signal cables and source are work as well-
Check Lamp Module
• Check Colour Wheel- Check DMD Board
• Check Main Board