3-4
No Symptom
Procedure
8 Colour Abnormal
• Do “Reset (All data)” of the OSD Menu
Adjust Colour Wheel Index
• Check Main Board- Check DMD Board
• Check Colour Wheel
9
Poor Uniformity/
Shadow
• Ensure the projection screen without dirt
• Ensure the projection lens is clean
• Ensure the Brightness is within spec
• Check rod alignment
• Check Engine Module
10
Dead Pixel/Dust
(Out of spec.)
• Ensure the projection screen without dirt
• Ensure the projection lens is clean
• Clean DMD Chip and Engine Module
• Check DMD Chip- Check Engine Module
11 Garbage Image
• Ensure that the signal cables and source work as well.
• Check Main Board
• Check DMD Board
12
Remote Control/
Control Panel Failed
• Remote Control
a. Check Battery
b. Check Remote Controller
c. IR receiver
d. Check Main Board
• Control Panel
a. Check FPC
b. Check key pad
c. Check Main Board
13
Function Abnormal
• Do “Reset (All data)” of the OSD Menu
• Check Main Board
• Check DMD Board

Table of Contents