User's Manual | ACOM 1010 | HF Linear Amplifier
Page
32
of
40
| S e c t i o n MAINTENANCE
July 2021
5.6. Service Functions
By pressing the OPER and RTTY buttons simultaneously, the upper LED bar-graph is switched to the
SERVICE mode, which is indicated by both red bar-graph lights and the yellow G1 light illuminating. Pressing
the OPER and RTTY buttons together again will select additional service measurement functions. Pressing
them a final time will return the amplifier to the normal operating mode. These steps are detailed below:
a) Press the OPER and RTTY buttons together. The two red lights on the right side of the upper
bar-graph will illuminate to confirm that the amplifier is in the service mode. The yellow G1
light will also illuminate. The upper bar-graph should show a grid 1 current reading no higher
than 5 mA (5 LEDs illuminated);
b) Pressing the OPER and RTTY buttons once again will now illuminate the yellow G2 light. This
provides an approximate reading of grid 2 voltage. The scale is 30 V per a LED lighted. The
upper bar graph should show a voltage reading within the range of either 270-300 Volts (9-10
LEDs illuminated) for RTTY or 210-330 Volts (7 to 11 LEDs illuminated) for SSB and CW;
c) Pressing the OPER and RTTY buttons yet again will illuminate the yellow IP light. This
provides an approximate reading of combined plate current and grid 2 current. The reading
should be no higher than 500 mA (10 LEDs illuminated) for RTTY or 600 mA (12 LEDs
illuminated) for SSB and CW. The scale is 50 mA per a LED lighted;
d) Pressing the OPER and RTTY buttons a final time will restore the upper bar-graph to its
normal function of indicating peak forward power.
The Auto-Protection System will continue to operate in the SERVICE mode.
In case it is necessary to ship the amplifier, please, see Section 6.3 Storage and Shipment.

Other manuals for Acom 1010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Acom 1010 and is the answer not in the manual?

Acom 1010 Specifications

General IconGeneral
Complies with CE safety and electromagnetic compatibility requirements, as well as FCC regulationsYes
Power Output1000 W PEP
ModesSSB, CW, RTTY, AM, FM
Power Supply200-240VAC or 100-120VAC, 50-60Hz, single phase.
CoolingForced air
Harmonic Output-50 dB
Input Impedance50 Ohms
Output Impedance50 Ohms
Tube4CX800A

Related product manuals