~ Measure a Specific Leakage
Source (Walk-About)
in the Field
At this stage of the manual, you have
identified a leakage source as a result
of patrolling. The procedures in this
section will assist you in identifying
the specific leakage source in the field.
1. Disconnect your meter from the
vehicles mounted antenna and/or the
docking station.
2. Gather the equipment needed to
conduct a site specific leakage test
Leakage meter (CLI-1450/1750)
dipole antenna (HD-1)
Adjustable 10-Foot Antenna Pole,
PL-1 (only required for FCC or CEN-
ELEC compliant measurements)
3. Press SHIFT and the Leakage key.
4. Change the antenna type to corre-
spond with your hand-held dipole
antenna (HD-1).
4-8
arrive at the antenna in-phase. After
accumulating at the antenna, you will
have twice the field-strength.
Standing Wave
Direct Path
Reflected Path