Acterna SDA-5000 Specifications

General IconGeneral
BrandActerna
ModelSDA-5000
CategoryMeasuring Instruments
LanguageEnglish

Summary

The SDA Family

Field Unit

Description of the SDA-5000 as a powerful multipurpose troubleshooting assistant for CATV test.

Description and Basic Operation

Sweep

Details on measuring frequency response of cable networks using forward, reverse, and other sweep modes.

Spectrum Analysis

Features of the advanced spectrum analysis capability for troubleshooting cable networks.

CONFIGURING THE SDA-5000

Guide to accessing and adjusting configuration options via the CONFIGURE menu.

Channel Plan Configuration

Setting channel plan parameters like video signal type, tuning sequence, and editing plans.

Field Sweeping with the SDA-5000

TEST POINT COMPENSATION

Accounting for system levels and test point losses for accurate measurements.

Sweep Receiver Configuration

Configuration details for sweeping, including controls and indicators for efficiency.

Reverse Sweep Operation (SDA-5000 OPT1)

Detailed explanation of sweeping the reverse path with specific operational steps.

Reverse Path Troubleshooting

PROBLEMS IN ADVANCED SERVICES

Discussion of common issues like noise accumulation and diverse ingress sources in reverse path.

CPD (COMMON PATH DISTORTION) ANALYSIS

Explanation of CPD as intermodulation distortion and its common causes.

Zero Span Measurements

Using Zero Span on a spectrum analyzer for TDMA signal analysis.

Measuring System Performance

MEASURING SIGNAL LEVELS

Measuring signal levels in Level, Tilt, and Scan modes for channel analysis.

CARRIER-TO-NOISE MEASUREMENTS

Measuring carrier-to-noise (C/N) ratios for accurate system performance assessment.

CSO/CBT Measurements

Measuring Composite Second Order (CSO) and Composite Triple Beat (CTB) distortions.

Spectrum Analyzer Mode

ZERO SPAN Submenu

Displays a single frequency over time, showing amplitude and allowing signal analysis.

PathTrak Field View (OPT3)

PATHtrak MODE OPERATION

Using Local and Remote traces to compare spectrum data from different locations.

Digital Analysis (QAM View OPT4)

Modulation Error Ratio (MER)

Analogous to S/N or C/N, measures signal power relative to total signal degradation.

QAM INGRESS MODE

Spectrum view of ingress noise, CSO/CTB, and other impairments under the digital signal.

CONSTELLATION MODE

Visualizing signal quality via constellation patterns to identify and troubleshoot impairments.

EQUALIZER MODE

Corrects reflections and frequency tilt, indicating reflection strength and equalizer effort.

Automatic Test

TEST LOCATIONS

Recording location-specific data for Auto Test reports, including creating and selecting locations.

PERFORMING AN AUTO TEST

Step-by-step guide to configuring and executing an Auto Test.

AUTO TEST RESULTS

Viewing and printing Auto Test results, including interval data and Pass/Fail summaries.

Files

STORING FILES

Procedures for storing measurements made with various modes as files.

SWEEP REFERENCES

Selecting, storing, and deleting sweep reference files for improved accuracy.

Description and Basic Operation of the SDA-5500 and 5510

Measurement Mode Selection Keys

Keys used to choose appropriate measurement modes like Level, Tilt, Scan, Sweep.

GLOBAL CONFIGURATION

Setup modes for the SDA-5500/5510: Global, Measurements, Channel Plan, Sweep, PathTrak, Diagnostics.

Channel Plan Setup

Setting nine or ten channel plan configuration options for the system.

Sweep Transceiver (SDA-5500)

Selecting and adjusting sweep parameters for the SDA-5500.

Reverse Sweep (SDA-5510)

Selecting and adjusting reverse sweep parameters for the SDA-5510.

Measuring the Carrier to Noise Ratio

Measuring C/N ratio of tuned channel or frequency using DSP technique.

Spectrum Analyzer Mode

Viewing the system spectrum with variable spans and dynamic range.

SDA-5500/SDA-5510 Sweep Configuration

FORWARD SWEEP CONFIGURATION (SDA-5500)

Connecting SDA-5500, setting levels/telemetry, creating channel plan, conducting sweep.

Setting Levels

Setting sweep levels relative to video carriers and forward telemetry signals.

Setting Forward Telemetry Levels and Frequencies

Configuring forward telemetry signal frequency and level for the SDA-5500.

Creating Channel Plans

Building a channel plan to designate active, scrambled, and inactive channels.

Quick Build Channel Plan Procedure

Step-by-step guide to building a new channel plan using default settings.

Editing A Channel Plan

Modifying channel parameters like enabled status, type, and frequency.

Testing the Transmitter Setup

Tips for debugging transmitter setup and connection before proceeding to the field.

CONFIGURING REVERSE SWEEP

Operation of the SDA-5500/5510 reverse sweep option, including setup and procedures.

Basic Reverse Sweep Procedure

Aligning amplifiers for reverse path by measuring response at the headend.

Wiring Connections

Connecting the SDA-5500/5510 for reverse sweep in single cable and dual cable networks.

Creating a New Reverse Sweep Channel Plan

Step-by-step process to create a new reverse sweep channel plan.

Testing the Transmitter Setup for Reverse Sweep

Tips for debugging transmitter setup and connection for reverse sweep.

Reverse Sweep Theory

Aligning amplifiers for reverse path by measuring response at the headend.

Appendix A: Application Notes

FORWARD SWEEP AND BALANCE

Step-by-step headend setup for forward sweep, including wiring and level settings.

Build Channel Plan (Configure; Channel Plan)

Procedure for building a forward channel plan using the Tx or StealthWare.

Common Forward Sweep Problems

Identification and solutions for common issues like standing waves, spikes, and no communication.

REVERSE SWEEP AND BALANCE

Step-by-step headend setup for reverse sweep, including wiring and plan creation.

Reverse Sweep Setup

Setting up reverse sweep parameters on SDA-5500 or SDA-5510.

Reverse Balancing and Sweeping

Determining reverse capability and balancing forward path before proceeding with reverse.

Common Return Sweep Problems

Common issues encountered during return sweep and their troubleshooting.

Appendix B: Specifications

Sweep Mode

Specifications for frequency range, display span, scale, and sweep rates.

Spectrum Mode

Specifications for spans, sweep rates, display scaling, dwell, and dynamic range.

Zero-Span Mode

Specifications for video BW, resolution BW, measurement BW compensation, and sweep times.