3-11
Storage Manager
The complete logical device address is composed of the following
fields:
Array groups are automatically assigned an address that
corresponds to the lowest logical device address used by a device in
that array group.
When an array group has been created, its logical device address
does not change if the drive with the lowest ID is replaced by a hot
spare. When a hot spare replacement occurs, the failed drive
automatically becomes the new hot spare. If you choose not to use
that drive as a hot spare, Storage Manager prompts you to select an
unused logical device address for that drive.
Example
If the lowest member device address for an array is HBA:0 Bus:1
ID:12 LUN:0, the LSU address is HBA:0 Bus:1 ID:12 LUN:0.
HBA The controller to which the device is attached. PCI bus slots
are scanned from lowest to highest looking for Adaptec
controllers. As Adaptec controllers are found, they are
assigned numbers incrementally, starting with 0.
Bus Channel number of the channel to which the device is
attached.
LUN The LUN for that device is normally 0.
Device The unique ID for that device. For an array this is the
lowest ID among the drives that make up the array.