EasyManua.ls Logo

ADEMCO Security System - SUMMARY OF AUDIBLE;VISUAL NOTIFICATION

ADEMCO Security System
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SUMMARY OF AUDIBLE/VISUAL NOTIFICATION
(FIXED WORD DISPLAY CONSOLES]
SOUND
LOUD, lNTERRUPTEfY
Console & External
LOUD. CONTINUOUS
Console & External
ONE SHORT BEEP
(not repeated)
Console only
ONE SHORT BEEP
(Once every 60 secmds)
Console only
ONE BEEP every 60 sac
Console only
TWO SHORT BEEPS
Console only
THREE SHORT BEEPS
Console only
RAPID BEEPING
Console only
SLOW BEEPING
Console onlv
CAUSE
FIRE ALARM
BURGLARYIAUDIBLE
EMERGENCY ALARM
a. SYSTEM DISARM
b. SYSTEM ARMING AlTEMPT
WITH AN OPEN ZONE
c. BYPASS VERIFY
SYSTEM IS IN TEST MODE
a. LOW BAITERY AT A XMTR
b. SYSTEM MAIN BAIT. WEAK
c. TROUBLE
ARM AWAY OR MAXIMUM
a.
ARM STAY OR INSTANT
b. ZONE OPENED WHILE SYS-
TEM IS IN CHIME MODE
c. ZONE
OPENED WHILE SYS-
TEM IS IN TEST MODE
MEMORY OF ALARM
ENTRY DELAYWARNING
If bell is used as external sounder, fire alarm is pulsed rin bur{
SJ
Iote: Also see Power FaikIra under TROUBLE CONDITI NS 01
DISPLAY
FIRE and ALARM are displayed; protection zone in alarm is displayed.
AfARM is displayed; protection zone in alarm is also displayed.
a. Only READY displayed. Green READY indicator (if present) is lit.
b. NOT READY is displayed, open protection zone number is displayed.
Green READY indicator (if present) is not lit.
c. The bypassed protection zone numbers are displayed. (Ona beep for each
number discdaved,) BYPASS displayed.
Open Zone identifications will appear,
a. BAT displayed with ID number of transmitter.
b. BAT displayed’with no transmitter ID.
c. CHECK displayed. Troubled protection zone is displayed.
AWAY and (if MAXIMUM) INSTANT are displayed
indicator is lit.
a. STAY and (if INSTANT) INSTANT are displayed. Red ARMED indicator is
b. CHIME displayed, Pressing */READY key will display opened zone.
c. Open protection zone number is displayed.
FIRE and/or AfARM is displayed; zone in alarm is displayed.
None during delay; Exceeding the delay time without disarming causes alarm,
ry/audible emergency is steady ring.
age 27.