ADTECH9 Series CNC Maintenance Manual
- 174 -
acceleration and deceleration
024 If tapping shaft has an encoder
Range : OFF ON
Unit : None
Authority : Operation admin or higher
Default : OFF
Effective time : Instant
Note : To set the tapping axis, that is, whether the tapping follower axis is
connected to the encoder
025 Tapping FPGA calculate spindle speed
Range : OFF ON
Unit : None
Authority : Operation admin or higher
Default : ON
Effective time : Instant
Note : To set to use FPGA to calculate spindle precision speed during tapping
026 Tapping start spindle acceleration filter
Range : OFF ON
Unit : None
Authority : Operation admin or higher
Default : ON
Effective time : Instant
Note : To set tapping spindle acceleration smoothing function
027 Tapping adjusting parameter Kp
Range :
Unit : None
Authority : Operation admin or higher
Default : 68.00
Effective time : Instant