ADTECH9 Series CNC Maintenance Manual
- 175 -
Note : To set tapping closed-loop adjusting parameters
(proportional-derivative-integral adjusting parameters) to use default
values
028 Tapping adjusting parameter Ki
Range :
Unit : None
Authority : Operation admin or higher
Default : 0.0
Effective time : Instant
Note : To set tapping closed-loop adjusting parameters
(proportional-derivative-integral adjusting parameters) to use default
values
029 Tapping adjusting parameter Kd
Range :
Unit : None
Authority : Operation admin or higher
Default : 0.6
Effective time : Instant
Note : To set tapping closed-loop adjusting parameters
(proportional-derivative-integral adjusting parameters) to use default
values
030 Filter coefficient of tapping adjusting parameter Kd
Range :
Unit : None
Authority : Operation admin or higher
Default : 500.0
Effective time : Instant
Note : Default value is generally used to set tapping closed loop adjustment
parameters

Table of Contents

Other manuals for Adtech ADTECH9 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Adtech ADTECH9 Series and is the answer not in the manual?

Adtech ADTECH9 Series Specifications

General IconGeneral
BrandAdtech
ModelADTECH9 Series
CategoryControl Systems
LanguageEnglish

Related product manuals