EasyManua.ls Logo

Advent Instruments AI-5620 - AI-E502 Alternate REN Loads; Extended Product Support and Warranty; Specifications; Telephone Interface

Default Icon
33 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18 AI-5620 User Guide
AI-E502 Alternate REN loads
By default, the AI-5620 comes installed with ringer loads conforming to the TIA-1063
standard (1 REN = 8.0 uF + 6.8k). As a factory installed option, the AI-E502 ringer loads
will replace the default loads with one of the following alternates:
AI-E502-Aus:
Australian AS/ACIF S004:2008 (1 REN = 1.0uF + 4.0k)
AI-E502-ETSI25:
ETSI 25 Hz TS 101 952-1-1 (1 REN = 2.2uF + 2.7k)
AI-E502-ETSI50:
ETSI 50 Hz TS 101 952-1-1 (1 REN = 1.0uF + 2.7k)
AI-E502-BT:
British Telecom BTNR315 (1 REN = 0.5uF + 6.8k)
AI-E502-NZ:
Telecom New Zealand PTC220 (1 REN = 1.0uF + 8.0k)
(Others values are available by request.)
4.4 Extended Product Support and Warranty
AI-K001 Additional One Year Warranty
The standard product support and warranty period for the instruments is one year. This
option increases the parts and labor warranty period for another year to a total of two
years from date of purchase on the instrument.
AI-K003 Additional Three-Year Warranty
The standard product support and warranty period for the instruments is one year. This
option increases the parts and labor warranty period for another three years to a total of
four years from date of purchase on the instrument.
4.5 Specifications
4.3.1 Telephone Interface
General:
DC Channel Measurements
Input Voltage Range
300 Volts peak Maximum
Voltage Measurement Accuracy
2% of reading, 100 mV
Input Current Range
120 mA, Maximum.
Current Measurement Accuracy
2% of reading, 100 µA
Common mode input range
200 Volts Maximum