On Hook DC impedance Range
1k to 20k, Programmable
On Hook DC impedance Accuracy
Off Hook DC impedance Range
50 to 1000 , Programmable
Off Hook DC impedance Accuracy
Maximum DC load Power dissipation
± 0.2 dB (50 Hz – 10 kHz)
AC input noise (low gain)
-55 dBV Full Bandwidth,
-68 dBV ITU 0.41 psophometric weighted, 600
AC input noise (High gain)
-70 dBV Full Bandwidth,
-86 dBV ITU 0.41 psophometric weighted, 600
Frequency Measurement Accuracy
0.1% 1 Hz (100 Hz to 10 kHz & > -45 dBv)
± 0.2 dB (50 Hz – 10 kHz), on hook
Resistive AC termination Range
Resistive AC Termination Accuracy
± 2 % (100 Hz to 4000 Hz)
Reactive AC termination Setting
TBR-21, German Zr, Optional
± 4.5 % (100 Hz to 4000 Hz)
1-6 REN*
1
programmable in 1 REN steps
RJ-11 (center two conductors used)
*1 or Ringer Equivalence Number REN ≡ 6.9k + 8uF
4.3.2 Input & Output
BNC Input:
± 0.2 dB, 50 Hz to 10 kHz
Unbalanced, Ground Referenced
0.2 dB, 50 Hz to 10 kHz
Tip/Ring, Tip/Ring with user selectable filters, Tone
Generator
3 (can be set to mirror hook state, ring detect status,
and FSK decoder output status)
Output Pin Maximum Sink Current
Output Pin Pull-up Resistance
Input Pin Low Level Input
0.8 Volts (for logic 0) Maximum
Input Pin High Level Input
2.0 Volts (for logic 1) Minimum