Aeronix GES - Gigabit Ethernet Switch Errata and Products; GES Management Processor Communication Issue

Default Icon
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GES Users Manual
Page 32 of 33
A device connected to the GES can connect to other devices on the network but cannot
communicate with the GES’s Management Processor.
Problem:
If the affected device has a MAC address where the last two bytes concatenated are less
than or equal to 1500 (0x5DC), the IP stack in the Management Processor will discard
the packet.
Workaround:
Change the two least significant MAC address bytes of the affected device to make them
larger than 1500 (0x5DC).