AFL Noyes OPM5 Specifications

General IconGeneral
ModelOPM5
ManufacturerAFL Noyes
CategoryTest Equipment
TypeOptical Power Meter
Wavelength Range800 nm to 1700 nm
Detector TypeInGaAs
Resolution0.01 dB
DisplayLCD
Wavelengths850 nm, 1300 nm, 1310 nm, 1550 nm, 1625 nm
Accuracy±0.2 dB
ConnectorFC, SC, ST
Storage Temperature-20 to +70 °C

Summary

Safety Information

General Information

Introduction

Overview of the User's Guide purpose.

Contacting NOYES Customer Service

Contact details for technical and sales support.

Unpacking and Inspection

Procedures for receiving and checking equipment for damage.

Recommended Accessories

List of necessary accessories for connecting instruments.

OPM-Series Optical Power Meters

OPM4 Model Overview and Ports

Detailed description and illustration of the OPM4 model's ports and display.

OPM4 Dual Function Key Operations

Explanation of primary and secondary key functions on the OPM4.

OPM4 Reference Setting and Display Screens

Procedures for setting references and understanding OPM4 power-up and auto-off display screens.

OPM4 Test Mode Display Readings

Detailed explanation of OPM4 test mode display elements and indicators.

OPM5 Optical Power Meters

OPM5 Model Overview and Ports

Explanation of OPM5 physical ports, display elements, and new features.

OPM5 Dual Function Key and Mode Operations

Explanation of OPM5 key functions and mode switching.

OPM5 Reference Setting and Data Storage

Procedures for setting references and storing measurements on OPM5.

OPM5 Test Mode Display Readings

Detailed explanation of OPM5 test mode display elements and indicators.

OPM5 File and Fiber Management

Instructions for managing files and fibers using the OPM5 File Manager.

OPM5 Viewing Stored References and Measurements

How to view stored references and store measurements on OPM5.

OPM5 Recall Mode for Stored Records

Viewing and managing stored test records using the OPM5 Recall Mode.

OPM5 Editing and Clearing Stored Data

Procedures for editing stored records and clearing files/fibers on OPM5.

OLS-Series Light Sources

OLS1-Dual LED Light Source Features

Description of OLS1-Dual LED light source features, ports, and indicators.

OLS1-Dual LED Operation and Controls

Detailed operation of the OLS1-Dual, including power, wavelength, and mode selection.

OLS2-Dual Laser Source

OLS2-Dual Laser Source Features and Ports

Description of OLS2-Dual laser source ports, indicators, and key features.

OLS2-Dual Output Adjust Mode Operation

How to enable and use the output adjust feature on the OLS2-Dual.

OLS2-Dual Mode Selection and Controls

Switching between WAVE ID, CW, and Tone modes on the OLS2-Dual.

OLS4 Integrated LED and Laser Light Source

OLS4 Light Source Features and Ports

Description of OLS4 light source ports, indicators, and key features.

OLS4 Wavelength and Tone Control

How to select wavelengths and control tone modes on the OLS4.

OLS7-3 Triple Wavelength Laser Source

OLS7-3 Triple Wavelength Source Features

Description of OLS7-3 triple wavelength source ports, indicators, and features.

OLS7-3 Mode and Wavelength Selection

How to select modes and wavelengths on the OLS7-3.

OLS7-FTTH Triple Wavelength Laser Source

OLS7-FTTH Triple Wavelength Source Features

Description of OLS7-FTTH triple wavelength source ports, indicators, and features.

OLS7-FTTH Mode and Wavelength Selection

How to select modes and wavelengths on the OLS7-FTTH.

Measuring Optical Power

OPM Optical Power Measurement Procedure

Step-by-step guide to measure optical power using an OPM.

Testing Multimode Links

Multimode Link Test: Set Reference

Procedure to set a reference for multimode link testing using one jumper.

Multimode Link Test: Verify Jumpers

Verifying the insertion loss of test jumpers for multimode links.

Multimode Link Test: Measure Insertion Loss

Measuring the insertion loss of a multimode link.

Testing Single-mode Links

Single-mode Link Test: Set Reference

Procedure to set a reference for single-mode link testing using one jumper.

Single-mode Link Test: Verify Jumpers

Verifying the insertion loss of test jumpers for single-mode links.

Single-mode Link Test: Measure Insertion Loss

Measuring the insertion loss of a single-mode link.

Maintenance Tips

Optical Port Cleaning Procedures

Instructions for cleaning OPM and OLS optical ports using various methods.

Equipment Repair and Calibration

Information on recommended repair and calibration services for NOYES equipment.

Battery Replacement Guide

Steps for replacing the batteries in NOYES test instruments.