Step Diagnostic Result Action
No Do a check of the
lubrication pump and
relay.
Do a check of the wiring to
the lubrication pump.
Do a check of the
lubrication pump. Use a
multimeter to see if there
is an internal short in the
lubrication pump motor.
1.6.3.8 Bale pressure system diagnostics
WARNING: The machine or parts can move without notification.
The machine and its parts are heavy and can cause death or injury.
Park the machine on a clean, hard and level area.
Set the parking brake to ON and install the wheel chocks.
If an implement is on the machine, lower the implement to the ground.
Stop the engine and remove the ignition key.
CAUTION: Personal Protective Equipment is mandatory.
This procedure can cause injury.
Put on Personal Protective Equipment when you do this procedure.
Hydraulic pressure not stable
Step Diagnostic Result Action
1 Was the air removed from
the hydraulic valve after
repairs on the hydraulic
system, or before the first
start of the machine?
Yes Calibrate the hydraulic
valve. See Calibrations.
No Remove the air from the
hydraulic system. Go to
step 2.
2 Is the hydraulic pressure
stable?
Yes Diagnostics complete.
No Calibrate the hydraulic
valve. To calibrate the
hydraulic valve, see the
Calibrations section.
1 General
34 SimplEbale
79037906A