Step Diagnostic Result Action
8 Do a check of the oil
pump reservoir. Is the
level of oil correct?
Yes Go to step 9.
No Add oil.
9 Do a check of the
hydraulic hoses. Are there
leaks or failures on the
hoses?
Yes Repair the hydraulic
hoses.
No Go to step 10.
10 Do a check of the drive
mechanism for the oil
pump. Does it operate
correctly?
Yes Go to step 11.
No Replace the oil pump
drive chain.
11 Rotate the oil pump and
do a check if it operates
correctly. Is the internal
key in good condition and
operating correctly?
Yes Go to step 12.
No Replace the oil pump.
12 Do a check of the
hydraulic valve. Are there
unwanted objects in the
valve stems?
Yes Clean the hydraulic valve
and remove the unwanted
objects.
No Refer to your approved
dealer.
Bale chamber pressure reduction does not function correctly
Step Diagnostic Result Action
1 Is the PTO speed less
than 70% of the standard
PTO speed?
Yes Go to step 2.
No Decrease the PTO speed.
2 Does the compression
cycle status indicator
illuminate on the Baler
Diagnostics page of the
terminal?
Yes For 1844 models: See
Hydraulics system not
building pressure
diagnostics.
No Refer to your approved
dealer.
1 General
36 SimplEbale
79037906A