SCPI COMMAND SUMMARY
SYSTem:DUMP:PRINter?
Causes a dump of the display contents to be made to the GPIB.
SYSTem:ERRor?
Returns the next message in the error queue. The format of the
response is :
<
error number
>
,
<
error string
>
where the error number is as shown in the \Error Messages" section
and error string is :
"
<
Generic HP-SL string
>
;
<
More specic information
>
"
An example resp onse to
SYST:ERR?
is
0
23,"NUMERIC OVERFLOW;YOU PUT IN A NUMBER TOO BIG"
SYSTem:LANGuage SCPI|CIIL|COMPatible
Causes the swept signal generator to p erform a language switchto
another language system.
SYSTem:MMHead:SELect:AUTO ON|OFF|0|1
SYSTem:MMHead:SELect:AUTO?
Sets and queries automatic selection of the millimeter source
mo dule interface connector. If the swept signal generator nds
a source mo dule connected at b oth the fron
t and the rear
connectors, the source mo dule at the front connector is selected.
Programming a sp ecic state via SYSTem:MMHead:SELect sets
SYSTem:MMHead:SELect:AUTO to OFF. *RST value is 1.
SYSTem:MMHead:SELect FRONt|REAR|NONE
SYSTem:MMHead:SELect?
Sets and queries the active millimeter source mo dule in
terface.
Programming a sp ecic state (FRONt
j
REAR
j
NONE) sets
SYSTem:MMHead:SELect:AUTO to OFF. Programming a sp ecic
state will cause the instrument to examine the selected interface to
determine the type of source mo dule connected. The instrument
frequency limits and multiplier will b e altered accordingly.However,
the leveling p ointis
not
changed (see POWer:ALC:SOURce).
SYSTem:PRESet[:EXECute]
Sets the swept signal generator to its \lo cal op eration" state. This
is the same as pressing the front panel \green" key. There is no
corresp onding query.
SYSTem:PRESet:SAVE
Saves the present state so it can be used whenever the command
SYSTem:PRESet[:EXECute]
is executed or the front panel \green"
key is pressed.
SYSTem:PRESet:TYPE FACTory|USER
SYSTem:PRESet:TYPE?
Operating and Programming Reference S-53

Table of Contents

Other manuals for Agilent Technologies 83650B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 83650B and is the answer not in the manual?

Agilent Technologies 83650B Specifications

General IconGeneral
BrandAgilent Technologies
Model83650B
CategoryPortable Generator
LanguageEnglish

Related product manuals