SCPI COMMAND SUMMARY
Sets and queries the type of preset to execute when the
SYSTem:PRESet[:EXECute]
command is given. Factory preset
defaults all values to factory sp ecied values. User dened preset
defaults all values to a sp ecied state of the swept signal generator
that you havesaved with
SYSTem:PRESet:SAVE
.
SYSTem:SECurity:COUNt <num>|MINimum|MAXimum
SYSTem:SECurity:COUNt? [MINimum|MAXimum]
Sets and queries the number of times to clear memory when the value
of SYSTem:SECurity[:STATe] changes from ON to OFF.
*RST value is 1.
SYSTem:SECurity[:STATe] ON|OFF|1|0
SYSTem:SECurity[:STATe]?
Controls the security mo de of the swept signal generator. When
in secure mo de, any display annunciators that have b een disabled
cannot b e re-enabled without destroying certain stored information.
This value is not aected by *RST. When you change the value
from ON to OFF, everything except calibration data is initialized or
destroyed. In particular, data in instrument state and all save/recall
registers are destroyed.
SYSTem:VERSion?
This query returns a formatted numeric value corresp onding to the
SCPI version number to which the swept signal generator complies.
The response has the form YYYY.V where the Ys represen
t the year
version (i.e. 1990) and the V represents an approved revision number
for that year. This is a query only and therefore do es not ha
vean
asso ciated *RST state.
TRIGger[:IMMediate]
Causes the trigger event to o ccur regardless of other settings in the
subsystem. This event do es not aect any other settings in this
subsystem.
This command has no eect unless the swept signal generator is in
the
wait for trig
state. If the swept signal generator is in the
wait for
trig
state, it p erforms its trigger action. This is an ev
ent and has no
*RST condition.
TRIGger:ODELay <num>[time suffix]|MAXimum|MINimum
TRIGger:ODELay? [MAXimum|MINimum]
Sets and queries the trigger output delay, the time between when
the source is settled, (when Bit 1 of the Standard Op eration Status
Register makes a negative transition), and the trigger out signal is
sent.
S-54 Operating and Programming Reference