MIL-STD-1553 Reference Manual
Chapter 9 – Bus Monitor Functions
Return Value
All API functions return API_OK if no error occurred. If the return value is not
equal to API_OK the function ApiGetErrorDescription can be used to obtain an
error description.
Figure 9.1.17-1 Monitor Buffer Pointer
Monitor Buffer Start address
captured before I of the
Capture Start event (Trigger)
captured after I of the
Capture Start event (Trigger)
area still initialized to zero
Monitor Buffer End Address
Note: If Etp > Monitor Buffer End Address, then the Monitor Buffer Fill Pointer of
the AIM board Bus Monitor wraps around to the Monitor Buffer Start
Address.