MIL-STD-1553 Reference Manual
Chapter 9 – Bus Monitor Functions
9.1.23 ApiCmdBMTIWIni
Prototype:
AiInt16 ApiCmdBMTIWIni ( AiUInt32 ul_ModuleHandle, AiUInt8 biu, AiUInt8 con, AiUInt8 eti,
AiUInt8 aei, AiUInt8 ti0, AiUInt8 ti1 );
Driver Command:
API_BM_INI_TIW (0xC3)
Purpose:
This function is used to arm the BM with the Triggers to be evaluated. The triggers
to be evaluated are stored into the Trigger Index Word according to the specified
input parameters.
I
I
n
n
p
p
u
u
t
t
A
A
i
i
U
U
I
I
n
n
t
t
8
8
c
c
o
o
n
n
External Trigger Index (= static Trigger)
Trigger Control Block Index
Any Error Index (= static Trigger)
Trigger Control Block Index
Sequence Trigger 0 Control Block Index (= dynamic Trigger)
Trigger Control Block Index
Sequence Trigger 1 Control Block Index (= dynamic Trigger)
Trigger Control Block Index