EasyManua.ls Logo

Aim MIL-STD-1553 - Page 392

Aim MIL-STD-1553
502 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MIL-STD-1553 Reference Manual
378
Chapter 9 Bus Monitor Functions
A
A
i
i
U
U
I
I
n
n
t
t
1
1
6
6
p
p
x
x
_
_
Q
Q
u
u
e
e
u
u
e
e
-
-
>
>
u
u
w
w
_
_
A
A
S
S
P
P
Q
Q
u
u
e
e
u
u
e
e
S
S
i
i
z
z
e
e
QueueId
Value
Description
0..11,
13 ..24
64..n
Number of kBytes reserved on the AIM
board (in Local RAM) for the data queue
12
API_SCOPE_QUEUE_SIZE
For Milscope the queue size is fixed 96kb
Note: For proper use, it is recommended to set the data queue size to at least
4096 (4 MB) for the BIU2 queue on 3910 boards!
A
A
i
i
U
U
I
I
n
n
t
t
1
1
6
6
p
p
x
x
_
_
Q
Q
u
u
e
e
u
u
e
e
-
-
>
>
u
u
w
w
_
_
E
E
x
x
e
e
c
c
u
u
t
t
i
i
o
o
n
n
K
K
e
e
y
y
0 (reserved)
A
A
i
i
U
U
C
C
h
h
a
a
r
r
p
p
x
x
_
_
Q
Q
u
u
e
e
u
u
e
e
-
-
>
>
x
x
_
_
L
L
o
o
c
c
a
a
l
l
S
S
p
p
e
e
c
c
.
.
a
a
u
u
c
c
_
_
F
F
i
i
l
l
e
e
N
N
a
a
m
m
e
e
[
[
2
2
5
5
6
6
]
]
uc_ LocalBufferType
Value
Description
0, 1, 4
-
This parameter is ignored for these buffer types
2
‘dir’
Name of the temporary directory name for this
data buffer type
3
‘name’
File name or name of the Named Pipe of the local
data queue buffer
A
A
i
i
U
U
I
I
n
n
t
t
3
3
2
2
p
p
x
x
_
_
Q
Q
u
u
e
e
u
u
e
e
-
-
>
>
x
x
_
_
L
L
o
o
c
c
a
a
l
l
S
S
p
p
e
e
c
c
.
.
u
u
l
l
_
_
M
M
e
e
m
m
S
S
i
i
z
z
e
e
uc_ LocalBufferType
Value
Description
0, 2..4
-
This parameter is ignored for these buffer types
1
n
Set the data buffer size to n bytes
v
v
o
o
i
i
d
d
*
*
p
p
x
x
_
_
Q
Q
u
u
e
e
u
u
e
e
-
-
>
>
x
x
_
_
L
L
o
o
c
c
a
a
l
l
S
S
p
p
e
e
c
c
.
.
p
p
v
v
_
_
H
H
a
a
n
n
d
d
l
l
e
e
NULL (reserved)
A
A
i
i
U
U
C
C
h
h
a
a
r
r
p
p
x
x
_
_
Q
Q
u
u
e
e
u
u
e
e
-
-
>
>
x
x
_
_
R
R
e
e
m
m
o
o
t
t
e
e
S
S
p
p
e
e
c
c
.
.
a
a
u
u
c
c
_
_
F
F
i
i
l
l
e
e
N
N
a
a
m
m
e
e
[
[
2
2
5
5
6
6
]
]
uc_ LocalBufferType
Value
Description
0, 1, 4
-
This parameter is ignored for these buffer types
2
‘dir’
Name of the temporary directory name for this
data buffer type
3
‘name’
File name or name of the Named Pipe of the
remote data queue buffer
A
A
i
i
U
U
I
I
n
n
t
t
3
3
2
2
p
p
x
x
_
_
Q
Q
u
u
e
e
u
u
e
e
-
-
>
>
x
x
_
_
R
R
e
e
m
m
o
o
t
t
e
e
S
S
p
p
e
e
c
c
.
.
u
u
l
l
_
_
M
M
e
e
m
m
S
S
i
i
z
z
e
e
uc_ LocalBufferType
Value
Description
0, 2..4
-
This parameter is ignored for these buffer types
1
n
Set the data buffer size to n bytes
v
v
o
o
i
i
d
d
*
*
p
p
x
x
_
_
Q
Q
u
u
e
e
u
u
e
e
-
-
>
>
x
x
_
_
R
R
e
e
m
m
o
o
t
t
e
e
S
S
p
p
e
e
c
c
.
.
p
p
v
v
_
_
H
H
a
a
n
n
d
d
l
l
e
e
NULL (reserved)
O
O
u
u
t
t
p
p
u
u
t
t
N
N
o
o
n
n
e
e
Return Value
A
A
i
i
I
I
n
n
t
t
1
1
6
6
All API functions return API_OK if no error occurred. If the return value is not
equal to API_OK the function ApiGetErrorDescription can be used to obtain an
error description.

Table of Contents

Other manuals for Aim MIL-STD-1553