MIL-STD-1553 Reference Manual
402
Chapter 9 Bus Monitor Functions
Primary or secondary bus on which the trigger is activated
Value
Constant
Description
0
API_SCOPE_SRC_PRIMARY
Primary Bus
1
API_SCOPE_SRC_SECONDARY
Secondary Bus
A
A
i
i
U
U
I
I
n
n
t
t
3
3
2
2
p
p
x
x
_
_
S
S
c
c
o
o
p
p
e
e
T
T
r
r
g
g
-
-
>
>
u
u
l
l
_
_
T
T
r
r
g
g
V
V
a
a
l
l
u
u
e
e
Trigger value that is used to compare against. The voltage range that this value is representing is
dependent on the coupling that was set with the function ApiCmdScopeSetup().
Coupling
Value
Description
Extern 30V
0..1023
Representing the voltage range of -15V..+15V (steps of 29.3mV)
Extern 3V
0..1023
Representing the voltage range of -1.5V..+1.5V (steps of 2.9mV)
Stub 30V
0..1023
Representing the voltage range of -15V..+15V (steps of 29.3mV)
Stub 3V
0..1023
Representing the voltage range of -1.5V..+1.5V (steps of 2.9mV)
A
A
i
i
U
U
I
I
n
n
t
t
3
3
2
2
p
p
x
x
_
_
S
S
c
c
o
o
p
p
e
e
T
T
r
r
g
g
-
-
>
>
u
u
l
l
_
_
T
T
r
r
g
g
V
V
a
a
l
l
u
u
e
e
2
2
Boundary for ‘Less than” trigger in Trigger mode API_SCOPE_MODE_GREATER_OR_LESS_THAN on
APE cards. The voltage range that this value is representing is dependent on the coupling that was set with
the function ApiCmdScopeSetup().
Coupling
Value
Description
Extern 30V
0..1023
Representing the voltage range of -15V..+15V (steps of 29.3mV)
Extern 3V
0..1023
Representing the voltage range of -1.5V..+1.5V (steps of 2.9mV)
Stub 30V
0..1023
Representing the voltage range of -15V..+15V (steps of 29.3mV)
Stub 3V
0..1023
Representing the voltage range of -1.5V..+1.5V (steps of 2.9mV)
Note: Tis parameter is only available on APE MILScope modules. On APX,
ACX MILScope modules this value must be set to zero.
A
A
i
i
U
U
I
I
n
n
t
t
3
3
2
2
p
p
x
x
_
_
S
S
c
c
o
o
p
p
e
e
T
T
r
r
g
g
-
-
>
>
u
u
l
l
_
_
T
T
r
r
g
g
N
N
b
b
S
S
a
a
m
m
p
p
l
l
e
e
s
s
Number of samples
‘ul_TrgMode’
Value
Description
0, 1
0
Reserved
3,4, 5
1..255
Number of samples
A
A
i
i
U
U
I
I
n
n
t
t
3
3
2
2
p
p
x
x
_
_
S
S
c
c
o
o
p
p
e
e
T
T
r
r
g
g
-
-
>
>
u
u
l
l
_
_
T
T
r
r
g
g
N
N
b
b
S
S
a
a
m
m
p
p
l
l
e
e
s
s
2
2
Reserved for future use only.
Note: Tis parameter is only available on APE MILScope modules. On APX,
ACX MILScope modules this value must be set to zero.
A
A
i
i
U
U
I
I
n
n
t
t
3
3
2
2
p
p
x
x
_
_
S
S
c
c
o
o
p
p
e
e
T
T
r
r
g
g
-
-
>
>
u
u
l
l
_
_
T
T
r
r
g
g
F
F
l
l
a
a
g
g
s
s
Trigger flags
Bit 31
Bit 30
Bit 29
Bit 28
Bit 27
Bit 26
Bit 25
Bit 24
reserved (0)
Bit 23
Bit 22
Bit 21
Bit 20
Bit 19
Bit 18
Bit 17
Bit 16
reserved (0)
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
reserved (0)
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
reserved (0)
DIS_FDBT
D
D
I
I
S
S
_
_
F
F
D
D
B
B
T
T
0: The Trigger is enabled immediately