Enter the program mode with the GT-NS-V/GT-NS, GT-DMV/GT-DM or GT-MK and select "SET TIMER".
Operation timer: If the operation panel is not operated for a certain period of time, the system returns to standby mode. The initial setting is 15
seconds.
Program timer: If an operation is not performed for a certain period of time in the program mode, the program mode will automatically be can-
celled. The initial setting is 60 seconds.
Call timer: Calls from entrance stations and security guard stations will expire after a certain period of time. The initial setting is 45 seconds.
Door release timer: Set the time for when the door is locked again after a door release operation. The initial setting is 0 seconds.
Entrance station (Unit type) door release timer: Set the GT-DA-L/GT-DA
with volume VR1.
Setting the input timeout timer5-10
Set the operation timer in the range from 15 to 99 seconds.
Set the program timer in the range from 30 to 99 seconds.
Set the call timer in the range from 30 to 99 seconds.
Set the door release timer in the range from 00 to 20 seconds.
If the timer is set at 00 seconds, the door will be released only
while the button is pressed.
GT-DMV/GT-DMGT-NS-V/GT-NS, GT-MK
OPERATION TIMER
15
SET TIMER
PROGRAM TIMER
60
CALL DURATION
45
MENU
:ENTER
ACCESS CODE
RESIDENT INFO.
SET TIMER
0
3
E
D
F
0
0
6
N
M
O
2
B
A
C
9
Y
X
W
Z
0
15~99
30~99
30~99
00~20
SET TIMER
OPERATION TIMER
15 s
INPUT 15-99
:QUIT
:NEXT
SET TIMER
PROGRAM TIMER
60 s
INPUT 30-99
:QUIT:NEXT
SET TIMER
CALL DURATION
45 s
INPUT 30-99
:QUIT
:NEXT
SET TIMER
RELEASE TIMER
15 s
INPUT 00-20
00=WHILE PRESSED
:QUIT
:NEXT
Next menu item
* Entrance stations (Integrated type) only
0.5 M
20
1
0
3
GT-DA-L/GT-DA
0.5 to 20: 0.5 to 20 seconds
M: While door release button is pressed

Other manuals for Aiphone GT SYSTEM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Aiphone GT SYSTEM and is the answer not in the manual?

Aiphone GT SYSTEM Specifications

General IconGeneral
Wiring2-wire
Door ReleaseYes
Operating Voltage24V DC
Wire Gauge18 AWG
TypeIntercom System
Power Source24V DC
InstallationSurface-mounted
CommunicationHands-free
ExpandabilityExpandable to multiple door stations and master stations
MountingWall-mount
Operating Temperature14°F to 140°F (-10°C to 60°C)
Humidity Range10% to 90% (non-condensing)
Frequency Response300 Hz to 3.4 kHz
Maximum Stations500
Maximum Door Stations32 door stations

Related product manuals