MOUNTING
Mounting locations
Appropriate cable
3-1
3-2
For video entrance stations and video door stations, the picture quality of residential station monitoring is affected by the nature of the external light
from above and the surrounding area of the built-in cameras, so do not install these stations in the types of locations shown below.
Locations exposed to direct sunlight
Locations under street lights or door lights
Other locations exposed to strong light
Use PE (polyethylene)-insulated PVC jacket cable.
Parallel or jacketed 2-conductor, mid-capacitance non-shielded cable is recommended.
Never use individual conductors, twisted pair cable or coaxial cable.
Install master monitor stations and sub master monitor stations in places where the screen is not exposed to direct sunlight.
• A switch
is located on the right side of the GT-2C-L/GT-2C, GT-2H-L/GT-2H, and GT-1C-L/GT-1C.
Allow open space of 5 cm (2").
At least 15 cm (6") of vertical open space from the center of the mounting bracket is needed for mounting the master monitor station or sub master
monitor station.
Entrance stations (Integrated type) include a sensor. Do not places objects such as plants or trees in places monitored by the sensor.
Also, placing the unit in bright sunlit areas may prevent the sensor from working properly.
Master monitor station
Sub master monitor station
15 cm
(6")
5 cm
(2")
Weak electrical current line connection
Length is 8 mm for the GT-DA-L/GT-DA, GT-DMV/GT-DM, GT-2C-L/GT-2C,
GT-2H-L/GT-2H, GT-1C-L/GT-1C, GT-BCX, GT-VBX, and GTW-LC; and 9 mm
for other units.
Insert the wire into the direct terminal. If it is difficult to insert the wire, insert it while
pressing the release button.
(x2)

Other manuals for Aiphone GT SYSTEM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Aiphone GT SYSTEM and is the answer not in the manual?

Aiphone GT SYSTEM Specifications

General IconGeneral
Wiring2-wire
Door ReleaseYes
Operating Voltage24V DC
Wire Gauge18 AWG
TypeIntercom System
Power Source24V DC
InstallationSurface-mounted
CommunicationHands-free
ExpandabilityExpandable to multiple door stations and master stations
MountingWall-mount
Operating Temperature14°F to 140°F (-10°C to 60°C)
Humidity Range10% to 90% (non-condensing)
Frequency Response300 Hz to 3.4 kHz
Maximum Stations500
Maximum Door Stations32 door stations